[Effects of PLGA absorbable membrane on preventing postoperative abdominal adhesion in rabbits].

Pang Xiubing, Pan Yongming, Hua Fei, Sun Chaoying, Chen Liang, Chen Fangming, Zhu Keyan, Xu Jianqin, Chen Minli

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effects of PLGA absorbable membrane in prevention of postoperative abdominal adhesion in rabbits.

METHODS

66 Japanese white rabbits were randomly divided into three groups: the normal control group n = 6, model control group n = 30 and PLGA group n = 30. Rabbits were received multifactor methods to establish postoperative abdominal adhesion models except for normal control group. The cecum wound was covered PLGA membrane in the PLGA group. At postoperative 1, 2, 4, 6 and 12 weeks, the abdominal cavities were reopened and the adhesive severity was graded blindly, and the hydroxyproline level in cecum tissue was measured and the cecum histopathology was observed.

RESULTS

(1) the degree of adhesion and hydroxyproline level in model control group were significantly higher than those of normal control group (P < 0.05, P < 0.01), while the degree of adhesion and hydroxyproline level in PLGA group were significantly lower than those of model control group (P < 0.05). (2) HE staining showed that cecum serosa had obviously inflammatory cell infiltration and fibroblast proliferation, while PLGA could inhibit fibroblast proliferation and reduce the inflammatory cell infiltration and collagen.

CONCLUSION

PLGA absorbable membrane can inhibit fibroblast proliferation and collagen to prevent the experimental postoperative peritoneal adhesions.

Для цитирования: Pang Xiubing, Pan Yongming, Hua Fei, Sun Chaoying, Chen Liang, Chen Fangming, Zhu Keyan, Xu Jianqin, Chen Minli. [Effects of PLGA absorbable membrane on preventing postoperative abdominal adhesion in rabbits].. Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.