The Annals of thoracic surgery · 2016
Pulmonary Valve Repair for Patients With Acquired Pulmonary Valve Insufficiency.
СтатьяVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Said Sameh M, Mainwaring Richard D, Ma Michael, Tacy Theresa A, Hanley Frank L
Аннотация
BACKGROUND: Pulmonary valve (PV) insufficiency is often an acquired condition after treatment for pulmonary stenosis. It is recognized that PV insufficiency has serious deleterious effects. Although surgical replacement of the PV is efficacious, artificial valves inevitably fail and require re-intervention. The purpose of this study was to summarize our experience with PV repair in patients with acquired PV insufficiency.
METHODS: This was a retrospective review of 16 patients with marked PV insufficiency who underwent PV repair. Thirteen of these patients were born with tetralogy of Fallot (TOF) and had undergone a previous transannular patch repair. Three patients were born with critical pulmonary stenosis and had a surgical valvotomy or balloon valvuloplasty.
RESULTS: The 13 patients with TOF had resection of their previously placed transannular patch with re-approximation of the anterior commissure. All 13 patients experienced a marked reduction in the degree of pulmonary insufficiency. None of these patients have experienced any increase in insufficiency during follow-up. The 3 patients with critical pulmonary stenosis had a variety of pathologic findings identified at the surgical procedure. One patient had a large gap between a commissure and underwent closure of that commissure. The second and third patients had torn leaflets repaired with pericardial and Gore-Tex patches (Gore, Inc, Flagstaff, AZ). The degree of PV insufficiency was decreased to mild in all 3 patients. However, 2 of these 3 patients have subsequently had an increase in the degree of pulmonary insufficiency.
CONCLUSIONS: Patients with TOF who underwent a previous transannular patch may be candidates for bicuspidization of their native PV, and the results of this procedure have been quite stable at follow-up. PV repair for torn leaflets was effective in the short term but was less stable over time.
METHODS: This was a retrospective review of 16 patients with marked PV insufficiency who underwent PV repair. Thirteen of these patients were born with tetralogy of Fallot (TOF) and had undergone a previous transannular patch repair. Three patients were born with critical pulmonary stenosis and had a surgical valvotomy or balloon valvuloplasty.
RESULTS: The 13 patients with TOF had resection of their previously placed transannular patch with re-approximation of the anterior commissure. All 13 patients experienced a marked reduction in the degree of pulmonary insufficiency. None of these patients have experienced any increase in insufficiency during follow-up. The 3 patients with critical pulmonary stenosis had a variety of pathologic findings identified at the surgical procedure. One patient had a large gap between a commissure and underwent closure of that commissure. The second and third patients had torn leaflets repaired with pericardial and Gore-Tex patches (Gore, Inc, Flagstaff, AZ). The degree of PV insufficiency was decreased to mild in all 3 patients. However, 2 of these 3 patients have subsequently had an increase in the degree of pulmonary insufficiency.
CONCLUSIONS: Patients with TOF who underwent a previous transannular patch may be candidates for bicuspidization of their native PV, and the results of this procedure have been quite stable at follow-up. PV repair for torn leaflets was effective in the short term but was less stable over time.
Предметные рубрики MeSH
Angioplasty, BalloonBioprosthesisCardiopulmonary BypassEchocardiography, TransesophagealHeart Valve Prosthesis ImplantationHumansPolytetrafluoroethylenePostoperative ComplicationsPulmonary ValvePulmonary Valve InsufficiencyPulmonary Valve StenosisReoperationRetrospective StudiesTetralogy of FallotTreatment Outcome