MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prosdent.2025.04.003

Медицинская библиотека · The Journal of prosthetic dentistry · 2025

Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study.

Arcuri Lorenzo, Pozzi Alessandro, Londono Jimmy, Nardi Alessandra, Testarelli Luca, Galli Massimo

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: Different scan body types have been reported to influence intraoral scanning accuracy. Stiff implant connections allow the use of snap-on scan bodies. However, data on the influence of scan body retention type are lacking.

PURPOSE: The purpose of this in vitro study was to assess and compare the accuracy of complete arch digital scanning with that of screw-retained or snap-on scan bodies.

MATERIAL AND

METHODS

An edentulous mandibular master model with 4 conical connection analogs was digitized with an extraoral optical scanner to achieve a reference file. Seventy-six test scans were obtained with an intraoral scanner: 38 using screw-retained and 38 using snap-on scan bodies. The resulting 76 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ- axis), and angular deviations (ΔANGLE) were evaluated for each implant position (n=304). Three-dimensional (3D) deviation was calculated for each position according to the Euclidean distance (ΔEUC). Descriptive analysis and multivariable analysis were stratified considering scan body type and implant position (α=.05).

RESULTS

Considering ΔEUC, scan body type showed no significant difference (P=.097), while implant position was statistically significant (P<.001), with the left second premolar as the most critical and the right lateral incisor the most accurate. Considering ΔANGLE, the snap-on scan bodies were significantly better (P=.033). The implant position also resulted in statistically significant differences (P<.001) with the left second premolar being the most critical and the right lateral incisor as the most accurate.

CONCLUSIONS

Snap-on scan bodies showed comparable 3D and higher angular accuracy compared with screw-retained scan bodies. Tilted posterior implants were the least accurate and resulted in more critical positions, especially the most distal position to be recorded.

Для цитирования: Arcuri Lorenzo, Pozzi Alessandro, Londono Jimmy, Nardi Alessandra, Testarelli Luca, Galli Massimo. Complete arch digital implant scan accuracy with screw-retained or snap-on scan bodies: A comparative in vitro study.. The Journal of prosthetic dentistry. 2025. DOI: 10.1016/j.prosdent.2025.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.