MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0036-1571827

Медицинская библиотека · The Thoracic and cardiovascular surgeon · 2016

Respiratory System Function in Patients after Aortic Valve Replacement through Right Anterior Minithoracotomy.

Stoliński Jarosław, Plicner Dariusz, Fijorek Kamil, Grudzień Grzegorz, Kruszec Paweł, Andres Janusz, Kapelak Bogdan

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Background The aim of the study was to analyze respiratory system function after minimally invasive aortic valve replacement through right anterior minithoracotomy (RAT-AVR). Methods An observational study of 187 patients electively scheduled for RAT-AVR between January 2010 and December 2013. Pulmonary complications were analyzed and spirometry examinations were performed preoperatively, 1 week, 1 month, and 3 months after surgery. Results Hospital mortality was 1.1%. A double-lumen intratracheal tube was used in 88.2% and single-lumen intratracheal tube was used in 11.8% of patients. Pulmonary complications occurred in 10.8% of the patients. Prolonged (>24 hours) mechanical ventilation time was present in five patients (2.7%). The reasons were stroke (n = 1), perioperative myocardial infarction (n = 2), and pneumothorax (n = 2). Right pleural effusion, which occurred in 7.7% (n = 14) of patients, was the most frequent respiratory system complication. One week after surgery, the spirometry parameters decreased in comparison to the preoperative period, then after 3 months statistically significant improvement occurred; however, the spirometry parameters still had not returned to preoperative values. Multivariable median regression analysis shows that the presence of chronic obstructive pulmonary disease and pulmonary complications were associated with lower values of forced expiratory volume in 1 second after surgery. There was no statistically significant difference regarding spirometry values or incidence of pulmonary complications after surgery between patients in whom single-lung or double-lung ventilation was applied. Conclusion Pulmonary functional status measured with spirometry parameters was diminished after RAT-AVR surgery. Single-lung ventilation did not result in a higher rate of respiratory complications after RAT-AVR surgery.

Для цитирования: Stoliński Jarosław, Plicner Dariusz, Fijorek Kamil, Grudzień Grzegorz, Kruszec Paweł, Andres Janusz, Kapelak Bogdan. Respiratory System Function in Patients after Aortic Valve Replacement through Right Anterior Minithoracotomy.. The Thoracic and cardiovascular surgeon. 2016. DOI: 10.1055/s-0036-1571827.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.