Enhanced Differentiation of Amiodarone-Induced Thyrotoxicosis Types Using Semi-Quantitative 99mTc-MIBI Uptake Analysis: A Pilot Study.
Аннотация
BACKGROUND Technetium (99mTc)-labelled Methoxy-2-Isobutylisonitrile (MIBI) is a diagnostic lipophilic cationic radiotracer used to evaluate the cardiac, breast, thyroid, and parathyroid pathology. This study aimed to evaluate the role of MIBI combined with Tc-99m pertechnetate thyroid scintigraphy, thyroid ultrasonography, and measurement of thyrotropin, thyroid hormones, and autoantibodies to subtype amiodarone-induced thyrotoxicosis (AIT) and the contribution of semi-quantitative analysis of MIBI uptake. MATERIAL AND METHODS This cross-sectional study included 36 patients with AIT who underwent thyrotropin, thyroid hormone, and autoantibody analysis using chemiluminescent method, ultrasonography, pertechnetate, and MIBI thyroid scintigraphy with semi-quantitative uptake, including calculation of the target-to-background ratio (TBR) with 2 different background regions. The MIBI washout rate (WR) was analyzed in all groups. Statistical analysis was performed using descriptive statistics, correlations, and the receiver operating characteristic curve - area under the curve (ROC-AUC). The results were compared with the control group. RESULTS Based on visual and semi-quantitative analyses, patients were successfully categorized into AIT groups (AIT-1, AIT-2 and AIT-3) but the latter method enabled better differentiation of MIBI uptake between all groups. Additionally, ROC-AUC analysis determined cutoff values which enabled discerning between AIT-1 and AIT-2 groups, and AIT-1 and AIT-3 groups. WR showed no significant difference between all AIT groups and controls (P>0.05). CONCLUSIONS Visual MIBI analysis enabled differentiation between AIT-1 and 2 groups, but the method was substantially improved with semi-quantitative analysis, especially in defining AIT-3 group. However, multicenter collaboration with larger studies is needed to standardize the method and obtain more accurate and consistent results.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.