The Annals of thoracic surgery · 2016
Transvenous Implantation of a Stent Valve in Patients With Degenerated Mitral Prostheses and Native Mitral Stenosis.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ahn Henrik Casimir, Baranowski Jacek, Dahlin Lars-Goran, Nielsen Niels Erik
Аннотация
BACKGROUND: The purpose of this study was to report the use of a transvenous transseptal approach using a stent valve in patients with degenerated biological mitral valve prostheses, regurgitation after mitral repair, and native mitral stenosis.
METHODS: Ten patients (median age, 74 years; range, 20-89 years; 5 men and 5 women) with degenerated mitral bioprosthetic valves (n = 7), failed mitral repair (n = 1), or calcified native stenotic valves (n = 2) underwent transvenous implantation of a stent valve.
RESULTS: The procedure was initially successful in all patients. Predilation was performed for balloon sizing only in the 2 patients with native mitral stenosis. The stent valve was deployed during 1 period of rapid pacing. A guidewire, as a loop from the right femoral vein and through the left ventricular apex, facilitated a good angle and secure positioning of the stent valve. An ultrasonographically guided puncture of the apex was carried out in 6 patients, and in the other 4 we performed a minithoracotomy before apical puncture. All valves were implanted in a good position with improved function and without significant paravalvular leakage (PVL). There were no periprocedural deaths. The 30-day survival was 80% (8 of 10 patients), and 60% (6 of 10) of patients were still alive a median time of 290 days after the procedure.
CONCLUSIONS: Transvenous transseptal implantation of a stent valve was performed in 10 patients with mitral valve disease, with good early functional results. These high-risk patients must be carefully selected by a multidisciplinary team because the procedure carries a high mortality.
METHODS: Ten patients (median age, 74 years; range, 20-89 years; 5 men and 5 women) with degenerated mitral bioprosthetic valves (n = 7), failed mitral repair (n = 1), or calcified native stenotic valves (n = 2) underwent transvenous implantation of a stent valve.
RESULTS: The procedure was initially successful in all patients. Predilation was performed for balloon sizing only in the 2 patients with native mitral stenosis. The stent valve was deployed during 1 period of rapid pacing. A guidewire, as a loop from the right femoral vein and through the left ventricular apex, facilitated a good angle and secure positioning of the stent valve. An ultrasonographically guided puncture of the apex was carried out in 6 patients, and in the other 4 we performed a minithoracotomy before apical puncture. All valves were implanted in a good position with improved function and without significant paravalvular leakage (PVL). There were no periprocedural deaths. The 30-day survival was 80% (8 of 10 patients), and 60% (6 of 10) of patients were still alive a median time of 290 days after the procedure.
CONCLUSIONS: Transvenous transseptal implantation of a stent valve was performed in 10 patients with mitral valve disease, with good early functional results. These high-risk patients must be carefully selected by a multidisciplinary team because the procedure carries a high mortality.
Предметные рубрики MeSH
AdultAgedAged, 80 and overBioprosthesisCalcinosisCardiac CatheterizationEchocardiography, TransesophagealEndovascular ProceduresFemaleFemoral VeinHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMaleMiddle AgedMitral Valve InsufficiencyMitral Valve StenosisPostoperative ComplicationsProsthesis FailurePulmonary VeinsReoperationThoracotomyUltrasonography, InterventionalYoung Adult