MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.70111

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2025

New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study.

Puig Josep, Dolz Guillem, Werner Mariano, Daunis-I-Estadella Pepus, Comas-Cufí Marc, Tomasello Alejandro, González Eva, Manso Del Caño Xabier, Vega Pedro, Murias Eduardo, Bravo Isabel, Jiménez Elvira, Aparici-Robles Fernando, Sanchís Juan Manuel, Remollo Sebastià, Castaño Carlos, Moreu Manuel, López-Frías Alfonso, Terceño Mikel, Silva Yolanda, Chirife Óscar, López-Rueda Antonio, Martínez-Fernández Javier, Méndez José Carlos, Sagredo Antonio, Díaz-Pérez José, Cuba Víctor, Llibre José Carlos, Aguilar Yeray, SanRoman Luis, Blasco Jordi, ROSSETTI Group

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Guidelines recommend stent retrievers (SRs) for treating large vessel occlusion (LVO) stroke. We assessed noninferiority of the iNtercept (iVascular) SR with a self-expanding basket on a pusher wire versus contemporary SRs (CSRs) using propensity score (PS) matching analysis.

METHODS

We analyzed data from the ROSSETTI multicenter registry of patients with anterior circulation LVO to compare procedural (recanalization rates according to the modified Thrombolysis In Cerebral Infarction (mTICI) score and procedural complications), clinical (modified Rankin Scale at 90 days), and safety (symptomatic intracranial hemorrhage, mortality at 90 days) outcomes of patients treated with iNtercept or CSRs (Solitaire, Trevo, and EmboTrap) as a first-line strategy, with or without balloon-guide catheter (BGC + SR, BCG - SR) after PS matching. Non-inferiority of iNtercept was established if the prespecified lower bound of the 95% confidence interval was over -10%.

RESULTS

A total of 164 and 132 patients treated first-line by iNtercept were matched to 656 and 132 patients treated first-line by CSR + BGC and CSR - BGC, respectively. After matching, successful reperfusion (mTICI2b/3) after first-line strategy was achieved in 53.7% and 54.8% in the iNtercept versus CSR + BGC groups, respectively (absolute difference, -0.1%), and 53.8% and 51.3% in the iNtercept versus CSR - BGC, respectively (2.6%). Final reperfusion rates and favorable 90-day outcomes were similar. iNtercept had fewer sICH, procedural complications, and emboli in a new territory than CSR + BGC, and fewer procedural complications than CSR - BGC.

CONCLUSIONS

This multicenter registry with PS matching demonstrated the non-inferiority of iNtercept to approved CSRs for successful reperfusion in LVO acute ischemic stroke.

Для цитирования: Puig Josep, Dolz Guillem, Werner Mariano, Daunis-I-Estadella Pepus, Comas-Cufí Marc, Tomasello Alejandro, González Eva, Manso Del Caño Xabier, Vega Pedro, Murias Eduardo, Bravo Isabel, Jiménez Elvira, Aparici-Robles Fernando, Sanchís Juan Manuel, Remollo Sebastià, Castaño Carlos, Moreu Manuel, López-Frías Alfonso, Terceño Mikel, Silva Yolanda, Chirife Óscar, López-Rueda Antonio, Martínez-Fernández Javier, Méndez José Carlos, Sagredo Antonio, Díaz-Pérez José, Cuba Víctor, Llibre José Carlos, Aguilar Yeray, SanRoman Luis, Blasco Jordi, ROSSETTI Group. New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2025. DOI: 10.1111/jon.70111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.