MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2026.06.016

Медицинская библиотека · Annals of vascular surgery · 2026

Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing.

Onishi Ryo, Okamoto Takeshi, Shimada Atsuki, Takamatsu Yuki, Okoshi Yuki, Suzuki Syuhei, Okubo Yuka, Nagasawa Ayako, Domae Keitaro, Mishima Takehito, Shiraishi Shuichi, Tsuchida Masanori

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Optimal device sizing for retrograde type A aortic dissection during thoracic endovascular aortic repair (TEVAR) remains challenging because the true lumen at the proximal landing zone is frequently compressed and elliptical. This study evaluated the clinical outcomes and investigated how true lumen morphology influences device selection.

METHODS

Between October 2012 and December 2022, 34 retrograde type A aortic dissection patients underwent TEVAR. Patients with major cardiac or neurological complications were excluded. We retrospectively analyzed the clinical and anatomical outcomes, focusing on postoperative remodeling. Preoperative computed tomography evaluated the relationship between the proximal landing true lumen morphology and device sizing.

RESULTS

The mean patient age was 62.7 ± 10.9 years. Emergency TEVAR was performed in 21 patients (61.8%) on the day of onset. Perioperative complications included one spinal cord infarction and no cerebral infarctions. Five patients required additional procedures for a residual entry flow. During the follow-up, the ascending aortic false lumen disappeared in 30 patients (88%). One in-hospital death occurred due to retrograde type A dissection related to stent-graft deployment. A proximal landing zone analysis showed frequently elliptical true lumens. The area-derived diameters tended to underestimate the size in highly elliptical lumens, whereas the major axis more closely corresponded to the selected device diameter.

CONCLUSION

TEVAR for retrograde type A aortic dissection is a feasible strategy with acceptable mid-to long-term outcomes in selected patients. Precise preoperative anatomical assessment and appropriate device sizing are essential to prevent complications. Evaluating the true lumen morphology at the proximal landing zone is critical for optimal device selection.

Для цитирования: Onishi Ryo, Okamoto Takeshi, Shimada Atsuki, Takamatsu Yuki, Okoshi Yuki, Suzuki Syuhei, Okubo Yuka, Nagasawa Ayako, Domae Keitaro, Mishima Takehito, Shiraishi Shuichi, Tsuchida Masanori. Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing.. Annals of vascular surgery. 2026. DOI: 10.1016/j.avsg.2026.06.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.