MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2018.07.203

Медицинская библиотека · World neurosurgery · 2018

Pipeline Embolization Device with Shield Technology for Intracranial Aneurysms: An Initial U.S. Experience.

Griessenauer Christoph J, Goren Oded, Dalal Shamsher S, Schirmer Clemens M

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Thromboembolic complications remain a major reason for morbidity and mortality after flow diversion, in addition to hemorrhagic complications not limited to the brain predicated on the prolonged need for dual antiplatelet therapy. Surface modification to decrease thrombogenicity and accelerate aneurysm occlusion is a promising alteration to mitigate those risks. The Pipeline embolization device with Shield Technology possesses such characteristics; however, it has not yet been approved in the United States.

CASE DESCRIPTION: We present the case of a 38-year-old woman with a Spetzler-Martin grade 4 left parietal arteriovenous malformation with a total of 8 feeding vessel aneurysms and recent rupture of 1 of those aneurysms that was treated with balloon-assisted coil embolization. Four M1-segment middle cerebral artery aneurysms and 1 supraclinoid internal carotid artery aneurysm were treated with 2 Pipeline embolization Shield devices after a compassionate use request was approved. At 3 weeks after the procedure, the patient experienced a minor ischemic stroke after having missed the prescribed dual antiplatelet therapy. At the 3-month follow-up examination, the patient was neurologically intact and all the aneurysms were occluded. Dual antiplatelet therapy was discontinued.

CONCLUSIONS

Flow diverters with surface modification to decrease thrombogenicity and accelerate aneurysm occlusion are promising endovascular tools for patients at high risk of complications with dual antiplatelet therapy. The present case represents one of the first cases performed in the United States using such a device. Despite the favorable outcome in the present case, the question of whether such technology obviates the need for dual antiplatelet therapy remains to be determined.

Для цитирования: Griessenauer Christoph J, Goren Oded, Dalal Shamsher S, Schirmer Clemens M. Pipeline Embolization Device with Shield Technology for Intracranial Aneurysms: An Initial U.S. Experience.. World neurosurgery. 2018. DOI: 10.1016/j.wneu.2018.07.203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.