Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failures?
Клиническое исследованиеСравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Johansson Björn, Bäck Tomas, Hirsch Jan-Michael
Аннотация
BACKGROUND: Bone grafts are frequently used to enable the placement of dental implants in atrophied jaws. The biomechanical properties of bone grafts used in one- or two-stage implant procedures (in comparison with the use of nongrafted bone) are not well known.
PURPOSE: The purpose of this study was (1) to measure cutting torques during the placement of self-tapping dental implants in nongrafted bone and in bone grafts, either as blocks or in a milled particulate form, in patients undergoing implant treatment in an edentulous maxilla and (2) to identify implants with reduced initial stability and to correlate these findings with a clinical classification of jawbone quality.
MATERIALS AND METHODS: The study included 40 consecutive patients with edentulous maxillas, 27 of whom were subjected to bone grafting prior to or in conjunction with implant placement (grafting group) and 13 of whom received implants without grafting (nongrafted group). Grafted bone from the iliac crest bone was used (1) as onlay blocks, (2) as maxillary sinus inlay blocks, or (3) in particulate form in the maxillary sinus. Implants were placed after 6 to 7 months of healing, except in the maxillary sinus inlay blocks, where implants were placed simultaneously. Cutting torque values were obtained from 113 grafted implant sites and from 109 nongrafted implant sites.
RESULTS: Significantly lower cutting torque values were assessed in grafted regions than in nongrafted regions, irrespective of grafting technique. Lower values were also seen for implants placed in block grafts after 6 months when compared to other grafting techniques used. The cutting torque values revealed an inverse linear relation to the Lekholm and Zarb bone quality index.
CONCLUSION: The cutting torque values correlated well with the Lekholm and Zarb index of bone quality. Significantly lower cutting torque values were seen in grafted bone than in nongrafted bone.
PURPOSE: The purpose of this study was (1) to measure cutting torques during the placement of self-tapping dental implants in nongrafted bone and in bone grafts, either as blocks or in a milled particulate form, in patients undergoing implant treatment in an edentulous maxilla and (2) to identify implants with reduced initial stability and to correlate these findings with a clinical classification of jawbone quality.
MATERIALS AND METHODS: The study included 40 consecutive patients with edentulous maxillas, 27 of whom were subjected to bone grafting prior to or in conjunction with implant placement (grafting group) and 13 of whom received implants without grafting (nongrafted group). Grafted bone from the iliac crest bone was used (1) as onlay blocks, (2) as maxillary sinus inlay blocks, or (3) in particulate form in the maxillary sinus. Implants were placed after 6 to 7 months of healing, except in the maxillary sinus inlay blocks, where implants were placed simultaneously. Cutting torque values were obtained from 113 grafted implant sites and from 109 nongrafted implant sites.
RESULTS: Significantly lower cutting torque values were assessed in grafted regions than in nongrafted regions, irrespective of grafting technique. Lower values were also seen for implants placed in block grafts after 6 months when compared to other grafting techniques used. The cutting torque values revealed an inverse linear relation to the Lekholm and Zarb bone quality index.
CONCLUSION: The cutting torque values correlated well with the Lekholm and Zarb index of bone quality. Significantly lower cutting torque values were seen in grafted bone than in nongrafted bone.
Предметные рубрики MeSH
Alveolar Bone LossAlveolar Ridge AugmentationBiomechanical PhenomenaBone DensityBone TransplantationDental Implantation, EndosseousDental ImplantsDental Prosthesis RetentionDental Restoration FailureFollow-Up StudiesHardness TestsHumansJaw, EdentulousMaxillaMaxillary DiseasesPredictive Value of TestsStress, MechanicalTorqueWound Healing