DOI 10.1016/j.jcrc.2025.155161
Impact of fluid removal rate on patients receiving continuous renal replacement therapy for acute kidney injury.
Аннотация
BACKGROUND
Fluid accumulation in severe acute kidney injury (AKI) has been associated with dialysis dependence and mortality. Less is known about the impact of fluid removal and its optimal rate with continuous dialysis.
METHODS
We conducted a single-center retrospective cohort study amongst adult patients admitted to the intensive care unit at the University of Chicago with AKI treated with continuous veno-venous hemodialysis (CVVHD) from April 1, 2016 to March 31, 2020. We collected baseline demographics, daily fluid balances, and patient outcomes. Weight adjusted fluid removal rates were calculated using the cumulative fluid balance over the first three days of CVVHD. Low fluid removal rate was defined as less than or equal to 1.01 mL/kg/h and high fluid removal rate as greater than 1.75 mL/kg/h.
RESULTS
We identified 1242 AKI patients treated with CVVHD. Baseline characteristics were compared on the basis of fluid removal rates. There were significant differences in rates of congestive heart failure, baseline weight, and cumulative fluid balance prior to CVVHD between the groups. 90-day mortality was highest (74 %) amongst those with low fluid removal rates. In an adjusted hazards model, low fluid removal rate was significantly associated with 90-day mortality (AHR 2.74(1.58-4.76)) but high fluid removal rate was not (AHR 0.50(0.30-1.03)).
CONCLUSIONS
In a large single center cohort, low fluid removal rate was an independent risk factor for 90-day mortality. High fluid removal rates may improve, but certainly do not worsen, outcomes. Clinical trials are needed to further investigate the optimal rates for fluid removal.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.