MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.14699

Медицинская библиотека · Contact dermatitis · 2024

Evaluation of validity, reliability and ability to detect change for the Hand Eczema Severity Index (HECSI) and evaluation of HECSI-75 and HECSI-90 as within-patient responder definitions.

Yüksel Yasemin Topal, Thoning Henrik, Larsen Lotte Seiding, Lehmann Lucine, Arbuckle Rob, Grant Laura, Agner Tove

СтатьяРандомизированное исследованиеВалидационное исследованиеКлиническое исследование II фазыПеревод в очереди

Аннотация

BACKGROUND

The Hand Eczema Severity Index (HECSI) is a Clinician-Reported Outcome measure of the severity of hand eczema (HE).

OBJECTIVES

This study aimed to evaluate the validity, reliability and ability to detect change of the HECSI, and the HECSI-75 and HECSI-90 as responder definitions.

METHODS

Analyses were performed using data from a sample of n = 258 patients with Chronic Hand Eczema (CHE) from a Phase 2b, randomised, double-blind, vehicle-controlled trial of delgocitinib cream, pooled across treatment groups. The measurement properties of the HECSI were assessed and the adequacy of the HECSI-75 and HECSI-90 as responder definitions was explored through cross-tabulation.

RESULTS

Inter-item correlations provided support for the scoring, whereby items are grouped by areas of the hand. HECSI demonstrated good test-retest reliability with intra-class correlations >0.70. Construct validity was supported by a logical pattern of correlations with concurrent measures and significant differences in HECSI scores across severity groups (p < 0.001). HECSI was responsive with statistically significant improvements over time and with significant differences (p < 0.001) between improved and stable groups. Data provided support for both HECSI-75 and HECSI-90 as within-patient responder definitions.

CONCLUSIONS

HECSI has strong validity, reliability and ability to detect change as a measure of CHE severity. HECSI-75 and HECSI-90 are appropriate responder definitions.

Для цитирования: Yüksel Yasemin Topal, Thoning Henrik, Larsen Lotte Seiding, Lehmann Lucine, Arbuckle Rob, Grant Laura, Agner Tove. Evaluation of validity, reliability and ability to detect change for the Hand Eczema Severity Index (HECSI) and evaluation of HECSI-75 and HECSI-90 as within-patient responder definitions.. Contact dermatitis. 2024. DOI: 10.1111/cod.14699.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.