Аннотация

AIMS: Electroanatomical voltage mapping (EAVM) is an important diagnostic tool for fibrosis identification and risk stratification in non-ischaemic cardiomyopathy (NICM); currently, distinct cut-offs are applied. We aimed to evaluate the performance of EAVM to detect fibrosis by integration with whole heart histology and to identify the fibrosis pattern in NICM patients with ventricular tachycardias (VTs).

METHODS AND

RESULTS

Eight patients with NICM and VT underwent EAVM prior to death or heart transplantation. EAVM data was projected onto slices of the entire heart. Pattern, architecture, and amount of fibrosis were assessed in transmural biopsies corresponding to EAVM sites. Fibrosis pattern in NICM biopsies (n = 507) was highly variable and not limited to mid-wall/sub-epicardium. Fibrosis architecture was rarely compact, but typically patchy and/or diffuse. In NICM, biopsies without abnormal fibrosis unipolar voltage (UV) and bipolar voltage (BV) showed a linear association with wall thickness (WT). The amount of viable myocardium showed a linear association with both UV and BV. Accordingly, any cut-off to delineate fibrosis performed poorly. An equation was generated calculating the amount of fibrosis at any location, given WT and UV or BV.

CONCLUSION

Considering the linear relationships between WT, amount of fibrosis and both UV and BV, the search for any distinct voltage cut-off to identify fibrosis in NICM is futile. The amount of fibrosis can be calculated, if WT and voltages are known. Fibrosis pattern and architecture are different from ischaemic cardiomyopathy and findings on ischaemic substrates may not be applicable to NICM.

Для цитирования: Glashan Claire A, Androulakis Alexander F A, Tao Qian, Glashan Ross N, Wisse Lambertus J, Ebert Micaela, de Ruiter Marco C, van Meer Berend J, Brouwer Charlotte, Dekkers Olaf M, Pijnappels Daniel A, de Bakker Jacques M T, de Riva Marta, Piers Sebastiaan R D, Zeppenfeld Katja. Whole human heart histology to validate electroanatomical voltage mapping in patients with non-ischaemic cardiomyopathy and ventricular tachycardia.. European heart journal. 2018. DOI: 10.1093/eurheartj/ehy168.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.