MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.5c06924

Медицинская библиотека · Analytical chemistry · 2026

Hydrophilicity-Differentiated Albumin Sensitivity of Polymethine Dyes in Vivo for Specialized Bioimaging.

Chen Min, Jiang Qinhong, Xie Mingli, Yu Lu, Wang Chunming, Wang Tenghui, Wei Huihui, Xing Panfei, Niu Yiming

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Polymethine dyes are invaluable tools for studying biological processes in vivo due to their superior fluorescence properties and biological functions. However, despite the availability of excellent polymethine dyes, their uncontrollable interactions with albumin often limits their applications to specialized contexts. In this study, we present a general strategy for modulating the albumin sensitivity of dyes through a hydrophilicity-differentiated bidirectional regulation approach. Experimental data and computational simulations demonstrate that sulfonate positioning is crucial for suppressing hydrophobic interaction-mediated albumin-dye binding. Furthermore, this effect is enhanced when coupled with an optimal length of the polymethine bridge, which governs the postbinding responsiveness of the dye. Together, these factors establish the regulatory basis for differentiating albumin-sensitive and insensitive dyes. Consequently, a hydrophilic and albumin-insensitive Cy5 was identified and constructed a probe, showing potential for detecting hepatic fibrosis in mice without albumin interference (a protein primarily produced in the liver). Conversely, an albumin-sensitive Cy5 was synthesized by reducing the hydrophilicity of a Cy5 framework with a high TICT tendency, which can monitor blood-brain barrier function in vivo.

Для цитирования: Chen Min, Jiang Qinhong, Xie Mingli, Yu Lu, Wang Chunming, Wang Tenghui, Wei Huihui, Xing Panfei, Niu Yiming. Hydrophilicity-Differentiated Albumin Sensitivity of Polymethine Dyes in Vivo for Specialized Bioimaging.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.5c06924.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.