Meningitis and a safe dexamethasone-eluting intracochlear electrode array.

Stathopoulos Dimitra, Chambers Scott, Adams Louise, Robins-Browne Roy, Miller Christopher, Enke Ya Lang, Wei Benjamin P C, O'Leary Stephen, Cowan Robert, Newbold Carrie

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the potential risk of pneumococcal meningitis associated with the use of a dexamethasone-eluting intracochlear electrode array as compared with a control array.

METHODS

In two phases, adult Hooded-Wistar rats were implanted via the middle ear with an intracochlear array and were inoculated with Streptococcus pneumoniae 5 days post-surgery. Phase I created a dosing curve by implanting five groups (n = 6) with a control array, then inoculating 5 days later with different numbers of S. pneumoniae: 0 CFU, 10(3) CFU, 10(4) CFU, 10(4) CFU repeated, or 10(5) CFU (colony forming units). A target infection rate of 20% was aimed for and 10(4) CFU was the closest to this target with 33% infection rate. In phase II, we implanted two groups (n = 10), one with a dexamethasone-eluting array, the other a control array, and both groups were inoculated with 10(4) CFU of S. pneumoniae 5 days post-surgery.

RESULTS

The dexamethasone-eluting array group had a 40% infection rate; the control array group had a 60% infection rate. This difference was not statistically significant with a P value of ≥0.5.

CONCLUSION

The use of a dexamethasone-eluting intracochlear electrode array did not increase the risk of meningitis in rats when inoculated with S. pneumoniae via the middle ear 5 days following implantation.

Для цитирования: Stathopoulos Dimitra, Chambers Scott, Adams Louise, Robins-Browne Roy, Miller Christopher, Enke Ya Lang, Wei Benjamin P C, O'Leary Stephen, Cowan Robert, Newbold Carrie. Meningitis and a safe dexamethasone-eluting intracochlear electrode array.. Cochlear implants international. 2014. DOI: 10.1179/1754762814y.0000000099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.