Journal of cardiovascular electrophysiology · 2013
Submammary device implantation in women: a step-by-step approach.
СтатьяVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Giudici Michael C, Meierbachtol Cynthia J, Paul Deborah L, Krupa Roselyn K, Vazquez Lauren D, Barold S Serge
Аннотация
INTRODUCTION: The frequency of device implantation is increasing in younger patients as our ability to diagnose long-QT syndrome, hypertrophic cardiomyopathy, Brugada Syndrome, and other life-threatening disorders earlier has improved. Similarly, use of cardiac resynchronization therapy and ICD therapies has increased in cardiomyopathy patients.
METHODS AND RESULTS: Device implantation in young women has unique considerations. Standard pectoral implants lead to excessive scar formation due to skin tension and interfere with purse straps, bra straps, and seat belts. There are also privacy and body image concerns as the subclavian region is exposed with many contemporary fashions.
RESULTS: Over an 11-year period, we implanted pacemakers, implantable converter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) devices (defibrillators or pacemakers) in 60 women, aged 13-70 years, using a 2-incision submammary approach. Follow-up surveys were performed using the Florida Patient Acceptance Survey (FPAS). Women with submammary device placement reported significantly greater device acceptance (M = 92.41, SD = 6.46) than women with standard implant technique (M = 70.29, SD = 17.85); t (54) =-6.08, P < 0.001, on the FPAS. Across subscales on the FPAS, women with submammary device placement also reported significantly less body image concern (P < 0.001), less device-related emotional distress (P < 0.001), and greater confidence in returning to life appropriately (P = 0.01) than women with standard device placement.
CONCLUSION: We present here our technique for submammary device implantation.
METHODS AND RESULTS: Device implantation in young women has unique considerations. Standard pectoral implants lead to excessive scar formation due to skin tension and interfere with purse straps, bra straps, and seat belts. There are also privacy and body image concerns as the subclavian region is exposed with many contemporary fashions.
RESULTS: Over an 11-year period, we implanted pacemakers, implantable converter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) devices (defibrillators or pacemakers) in 60 women, aged 13-70 years, using a 2-incision submammary approach. Follow-up surveys were performed using the Florida Patient Acceptance Survey (FPAS). Women with submammary device placement reported significantly greater device acceptance (M = 92.41, SD = 6.46) than women with standard implant technique (M = 70.29, SD = 17.85); t (54) =-6.08, P < 0.001, on the FPAS. Across subscales on the FPAS, women with submammary device placement also reported significantly less body image concern (P < 0.001), less device-related emotional distress (P < 0.001), and greater confidence in returning to life appropriately (P = 0.01) than women with standard device placement.
CONCLUSION: We present here our technique for submammary device implantation.
Предметные рубрики MeSH
Activities of Daily LivingAdolescentAdultAgedBody ImageCardiac Resynchronization Therapy DevicesCicatrixDefibrillators, ImplantableFemaleHumansMiddle AgedPacemaker, ArtificialPatient SatisfactionProsthesis ImplantationStress, PsychologicalSurveys and QuestionnairesTime FactorsTreatment OutcomeYoung Adult