MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20241126-05

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2025

Rotational Stability and Outcomes of V4c Toric Implantable Collamer Lenses Placed at Different Lens Orientations.

Yang Yukun, Zhu Fengjiao, Ma Yiping, Li Jing, Li Xiaoxi, Yao Xiaoming

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the 12-month rotational stability and outcomes of V4c toric Implantable Collamer Lenses (TICLs) (STAAR Surgical) located at two different lens orientations (horizontal or oblique).

METHODS

This retrospective study included a total of 403 eyes with TICL implantation, enrolled between January 2021 and December 2022, that were divided into two groups based on the minimum intended angle off the horizontal axis: horizontal with 263 eyes at an angle ±22.5 degrees or less and oblique with 140 eyes at a minimum intended angle of greater than ±22.5 degrees. A comparison was made of the preoperative characteristics, surgical outcomes, secondary surgical interventions, footplate positions, and adverse events at 1, 6, and 12 months postoperatively. The rotation-related factors were analyzed.

RESULTS

At 12 months, there were 243 eyes (92%) in the horizontal group and 130 eyes (93%) in the oblique group that were within ±0.50 diopters (D) of emmetropia. Their rotation proportion was 5.3 % and 5.7%, respectively, and their rotation angle was 9.11 ± 2.84 and 9.96 ± 2.42 degrees, respectively (P = .086). TICL footplates were mostly positioned on the ciliary body. No correlation was observed of lens placement axis, vault, or manifest refraction with rotation in both groups (P > .05). During the follow-up, no vision-threatening complications were observed in both groups. Rotation cases were successfully addressed via alignment or lens exchange.

CONCLUSIONS

TICLs, when implanted across a range of lens orientations, demonstrated favorable rotational stability and postoperative outcomes. The postoperative rotational stability is independent of the placement angle of the TICL. [J Refract Surg. 2025;41(1):e29-e38.].

Для цитирования: Yang Yukun, Zhu Fengjiao, Ma Yiping, Li Jing, Li Xiaoxi, Yao Xiaoming. Rotational Stability and Outcomes of V4c Toric Implantable Collamer Lenses Placed at Different Lens Orientations.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2025. DOI: 10.3928/1081597x-20241126-05.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.