MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2014.03.011

Медицинская библиотека · Journal of cardiology · 2014

Phonocardiogram in adult patients with tetralogy of Fallot.

Mizuno Atsushi, Niwa Koichiro, Shirai Takeaki, Shiina Yumi

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Right ventricular outflow tract (RVOT) stenosis and pulmonary regurgitation (PR) are important residua and sequelae in adult tetralogy of Fallot (TOF) patients. Auscultation of the heart sound is a useful tool to detect and evaluate these lesions, but there was no previous report regarding heart sound in adult TOF.

METHODS

We enrolled consecutive TOF outpatients from January 2013 to October 2013 in our adult congenital heart disease clinic. Phonocardiogram with phono-recording was performed with MES-1000 (Fukuda-Denshi Co., Tokyo, Japan), and compared heart sound with echocardiographic parameters.

RESULTS

A total of 30 TOF patients were enrolled [age, 34.7±12.8 years; 14 males (46.7%)]. In all 30 patients, phonocardiography was clearly recorded. Eighteen patients (60.0%) had the single second heart sound, which was more frequently observed before than after pulmonary valve reoperation (75.0% vs 11.1%). The single second heart sound was also associated with PR. In 18/30 (60%), diastolic murmur was associated with moderate PR (p=0.008). In 14/30 (46.7%), systolic murmur was associated with moderate RVOT stenosis (p=0.012).

CONCLUSION

Phonocardiogram was a useful tool to detect RVOT lesions. We should listen to heart sound carefully especially focusing on the second heart sound, systolic, and diastolic murmur.

Для цитирования: Mizuno Atsushi, Niwa Koichiro, Shirai Takeaki, Shiina Yumi. Phonocardiogram in adult patients with tetralogy of Fallot.. Journal of cardiology. 2014. DOI: 10.1016/j.jjcc.2014.03.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.