DOI 10.1080/14796694.2025.2595688
A deep learning radiomics model for predicting non-sentinel lymph node metastases in early-stage breast cancer patients.
Аннотация
AIMS: To develop and validate a deep learning radiomics model to predict non-sentinel lymph node (NSLN) metastases in early-stage breast cancer patients with 1-2 positive sentinel lymph node (SLN) metastases.
METHODS
This retrospective and prospective study encompassed 1,647 patients. Clinical, pathological information, and axillary ultrasound (AUS) findings, collected. Radiomic features of breast cancer lesions were extracted from the ultrasound images. We developed predictive models based on clinical factors alone (C model), clinical factors coupled with AUS (CA model), and clinical factors integrated with both AUS and radiomic features (CAR model). The predictive performance of each model was evaluated via the area under the curve (AUC), decision curve analysis (DCA), and calibration curve analysis.
RESULTS
The AUC values for the C model, CA model and CAR model in the test cohort were 0.812, 0.850, and 0.994, respectively. Notably, the CAR model exhibited significantly superior predictive capability compared to both the C model and CA model. In subgroups analyses, the CAR model also achieved the optimal predictive performance. The DCA curve confirmed that the CAR model possessed significant clinical implications.
CONCLUSIONS
The CAR model had the capability to predict NSLN metastases in early-stage breast cancer with 1-2 positive SLN metastases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.