A cylindrical projection lithography-fabricated flexible on-catheter in situ integrated sensor for continuous in-artery blood pressure monitoring.

Ye Fengming, Hou Jianwei, Li Xuanyu, Ni Jie, Li Mengqiu, Wang Jiaxiang, Yu Yangtao, Hu Zhiyuan, Li Yahui, Zang Faheng, Ding Guifu, Sun Bin, Su Kaiming, Guo Xiaojun, Liang Fuyou, Yang Zhuoqing

СтатьяПеревод в очереди

Аннотация

Continuous and accurate blood pressure monitoring is vital for the diagnosis and management of life-threatening cardiovascular diseases. Conventional fluid-filled catheter systems are fundamentally constrained by distortion, infection risks, and limited portability. In parallel, Micro-Electro-Mechanical System (MEMS) sensors assembled to catheters face miniaturization bottlenecks and packaging complexity. Here, we present a flexible on-catheter interventional pressure sensor (CIPS), leveraging suspended-graphene arrays for pressure sensing and dual polymer encapsulation layers for hermetic and waterproof encapsulation. The highly integrated CIPS with compact architecture is enabled by cylindrical projection lithography (CPL)-based 3D in situ MEMS fabrication process. By introducing interdigital electrodes (IDEs) in sensitive areas and optimizing structural parameters, CIPS delivers an ultrafast response (<0.36 s), exceptional sensitivity (3.5 × 10⁻⁶·mmHg⁻¹), and a broad detection range (6-380 mmHg), outperforming state-of-the-art suspended-graphene pressure sensors. The dual-layer polymer encapsulation strategy ensures the hermetic and waterproof integrity of CIPS. Crucially, CIPS enables real-time monitoring of arterial pressure in the rat abdominal aorta, marking the first demonstration of suspended graphene in animal-level bioelectronic sensing. This work has also underscored the translational potential for CPL-based 3D in situ MEMS fabrication strategy.

Для цитирования: Ye Fengming, Hou Jianwei, Li Xuanyu, Ni Jie, Li Mengqiu, Wang Jiaxiang, Yu Yangtao, Hu Zhiyuan, Li Yahui, Zang Faheng, Ding Guifu, Sun Bin, Su Kaiming, Guo Xiaojun, Liang Fuyou, Yang Zhuoqing. A cylindrical projection lithography-fabricated flexible on-catheter in situ integrated sensor for continuous in-artery blood pressure monitoring.. Microsystems & nanoengineering. 2026. DOI: 10.1038/s41378-026-01242-z.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.