DOI 10.1038/s41598-025-99273-5

Медицинская библиотека · Scientific reports · 2025

Clinical performance validation and four diagnostic strategy assessments of high-sensitivity troponin I assays.

Wu Junyi, Hua Yaotong, Ge Yilin, Chen Ke, Chen Siyu, Yang Jiashu, Yuan Hui

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Acute coronary syndrome (ACS) includes conditions such as unstable angina (UA), non-ST elevation myocardial infarction (NSTEMI), and ST elevation myocardial infarction (STEMI). High-sensitivity cardiac troponin I (hs-cTnI) assays have been recommended as primary biomarkers for NSTEMI diagnosis due to their high sensitivity and specificity. However, there is no consensus on the optimal diagnostic strategy for early NSTEMI detection. This study aims to evaluate the diagnostic performance of four hs-cTnI-based strategies for suspected NSTEMI: Limit of Detection (LoB), Single Cut-off, hs-cTnI 0/1 h Algorithm, and hs-cTnI 0/2 h Algorithm, in a Chinese cohort and compare the performance of assays from different manufacturers. Performance verification was conducted, including LoB, LoD, LoQ, and precision analysis. Clinical samples from 267 ACS patients were analyzed using Hybiome hs-cTnI assays. Diagnostic accuracy was assessed based on sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score. The LoB strategy demonstrated 100% sensitivity but low PPV (14.0%). Both the hs-cTnI 0/1 h Algorithm and hs-cTnI 0/2 h Algorithm showed high diagnostic performance, with the 0/2 h algorithm providing the best overall. 89.0% accuracy, 93.3% sensitivity, and 73.68% F1-score. The hs-cTnI 0/2 h Algorithm offers the most reliable diagnostic performance for early NSTEMI diagnosis.

Для цитирования: Wu Junyi, Hua Yaotong, Ge Yilin, Chen Ke, Chen Siyu, Yang Jiashu, Yuan Hui. Clinical performance validation and four diagnostic strategy assessments of high-sensitivity troponin I assays.. Scientific reports. 2025. DOI: 10.1038/s41598-025-99273-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.