BACKGROUND

Mutations in the alpha-l-iduronidase A (IDUA) gene cause mucopolysaccharidosis type I (MPS I), a progressive multisystem disorder with features ranging over a continuum from mild to severe which is inherited in an autosomal recessive manner. To date over 100 mutations are known, nonetheless genotype-phenotype prediction is complicated and hampered due to attenuating polymorphisms, rare sequence variants, varied genetic backgrounds and environmental effects.

METHODS

In this study we report the first development of a denaturating high performance liquid chromatography (dHPLC) protocol for the rapid and accurate detection of recently described mutations in the IDUA gene. Optimal PCR running and dHPLC partial denaturing conditions for mutation detection were established for each PCR amplicon corresponding to 14 IDUA exons and their adjacent intronic/flanking sequences.

RESULTS

A total of 12 different mutations, 5 nonsense, 4 missense, 1 deletion, and 2 splice site (intron), in 10 MPS I patients were screened. All mutations revealed a distinct dHPLC pattern thus enabling their accurate detection.

CONCLUSIONS

A dHPLC screening method was developed for the detection of mutations and sequence variants in the IDUA gene and the results presented in this study revealed that this promising method proved to be robust, automated, economical and above all, highly sensitive. Costs for the detection of mutations causing MPS I disease should be reduced by using this method as a pre-analytical tool followed by sequencing of aberrant heteroduplex-forming amplicons.

Для цитирования: Kasper David C, Iqbal Furhan, Dvorakova Lenka, Zeman Jiri, Magner Martin, Bodamer Olaf, Pollak Arnold, Herkner Kurt R, Item Chike B. Rapid and accurate denaturating high performance liquid chromatography protocol for the detection of alpha-l-iduronidase mutations causing mucopolysaccharidosis type I.. Clinica chimica acta; international journal of clinical chemistry. 2009. DOI: 10.1016/j.cca.2009.11.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.