MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2023.05.014

Медицинская библиотека · JACC. Clinical electrophysiology · 2023

Worldwide Experience With an Irrigated Needle Catheter for Ablation of Refractory Ventricular Arrhythmias: Final Report.

Tedrow Usha B, Kurata Masaaki, Kawamura Iwanari, Batnyam Uyanga, Dukkipati Srinivas, Nakamura Tomofumi, Tanigawa Shinichi, Fuji Akira, Richardson Travis D, Kanagasundram Arvindh N, Koruth Jacob S, John Roy M, Hasegawa Kanae, Abdelwahab Amir, Sapp John, Reddy Vivek Y, Stevenson William G

СтатьяМногоцентровое исследованиеКлиническое исследованиеПеревод в очереди

Аннотация

BACKGROUND

We previously reported feasibility of irrigated needle ablation (INA) with a retractable 27-G end-hole needle catheter to treat nonendocardial ventricular arrhythmia substrate, an important cause of ablation failure.

OBJECTIVES

The purpose of this study was to report outcomes and complications in our entire INA-treated population.

METHODS

Patients with recurrent sustained monomorphic ventricular tachycardia (VT) or high-density premature ventricular contractions (PVCs) despite radiofrequency ablation were prospectively enrolled at 4 centers. Endpoints included a 70% decrease in VT frequency or PVC burden decrease to <5,000/24 h at 6 months.

RESULTS

INA was performed in 111 patients (median: 2 failed prior ablations, 71% nonischemic heart disease, and left ventricular ejection fraction 36% ± 14%). INA acutely abolished targeted PVCs in 33 of 37 patients (89%), and PVCs were reduced to <5,000/day in 29 patients (78%). During 6-month follow-up, freedom from hospitalization was observed in 50 of 72 patients with VT (69%), and improvement or abolition of VT occurred in 47%. All patients received multiple INA applications, with more in the VT group than in the PVC group (median: 12 [IQR: 7-19] vs 7 [5-15]; P < 0.01). After INA, additional endocardial standard radiofrequency ablation was required in 23% of patients. Adverse events included 4 pericardial effusions (3.5%), 3 cases of (anticipated) atrioventricular block (2.6%), and 3 heart failure exacerbations (2.6%). During 6-month follow-up, 5 deaths occurred; none were procedure-related.

CONCLUSIONS

INA achieves improved arrhythmia control in 78% of patients with PVCs and avoids hospitalization in 69% of patients with VT refractory to standard ablation at 6-month follow-up. Procedural risks are acceptable. (Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia, NCT01791543; Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias, NCT03204981).

Для цитирования: Tedrow Usha B, Kurata Masaaki, Kawamura Iwanari, Batnyam Uyanga, Dukkipati Srinivas, Nakamura Tomofumi, Tanigawa Shinichi, Fuji Akira, Richardson Travis D, Kanagasundram Arvindh N, Koruth Jacob S, John Roy M, Hasegawa Kanae, Abdelwahab Amir, Sapp John, Reddy Vivek Y, Stevenson William G. Worldwide Experience With an Irrigated Needle Catheter for Ablation of Refractory Ventricular Arrhythmias: Final Report.. JACC. Clinical electrophysiology. 2023. DOI: 10.1016/j.jacep.2023.05.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.