MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.12120

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2014

Benefit of cone-beam CT angiography in visualizing aneurysm shape and identification of exact rupture site.

Lauric Alexandra, Heller Robert S, Schimansky Sarah, Malek Adel M

Клинический случайСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

While high-resolution cone-beam computational tomographic (CBCT) angiography has gained use in intracranial vascular imaging, digital subtraction angiography (DSA) and 3-dimensional-rotational angiography (3D-RA) remain the preferred acquisition modalities for intracranial aneurysm imaging. This case report highlights the utility of the greater spatial resolution afforded by CBCT for cerebral aneurysm imaging. A 54-year-old man presenting with subarachnoid hemorrhage was confirmed to harbor a ruptured anterior communicating artery aneurysm by conventional angiography. Due to varying contrast opacification captured by different acquisition methods, dramatic aneurysm shape difference was observed between 2- and 3-dimensional-angiographic and CBCT models. The greater resolution of CBCT revealed in an unequivocal fashion the exact site of rupture on the aneurysm dome, visualized as a discrete irregular and elongated bleb that was not seen on either 3D-RA or DSA. High-resolution CBCT visualized the shape of the target aneurysm in greater detail than the more conventional 2D-DSA and 3D-RA, enabling more precise computational fluid dynamics (CFD) simulations. Given that aneurysms most likely change shape either prior to rupture or upon rupture, future studies evaluating fluid dynamics using computer reconstructions should be cognizant of the differences in resolution provided by various imaging modalities.

Для цитирования: Lauric Alexandra, Heller Robert S, Schimansky Sarah, Malek Adel M. Benefit of cone-beam CT angiography in visualizing aneurysm shape and identification of exact rupture site.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2014. DOI: 10.1111/jon.12120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.