MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31661/gmj.v13i.3309

Медицинская библиотека · Galen medical journal · 2024

Comparison of Thyroid Gland Sonography Index with Serum Antithyroid Peroxidase, Antithyroglobulin, and Thyroid Function Tests in Patients with Hashimoto Thyroiditis.

Eftekharian Fatemeh, Ranjbar Omrani Gholamhossein, Dabbaghmanesh Mohammad Hossein, Sahraei Reza, Behnam Mohammad Ali, Bakhshayeshkaram Marzieh, Dabbaghmanesh Mohammad Mahdi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ultrasound examination of the thyroid has emerged as a useful diagnostic and prognostic tool, along with measuring serum titers of anti-thyroid peroxidase (TPO), anti-thyroglobulin (Tg), and thyroid hormones, in patients with Hashimoto's thyroiditis. So, we aimed at considering correlations of ultrasonographic, antibodies, and thyroid hormone levels.

MATERIALS AND

METHODS

A total of 149 patients (118 females, 31 males; aged 18-60 years; mean age: 38.60 ± 8.03 years) who were diagnosed with Hashimoto's thyroiditis were enrolled in the study. The blood sample was taken to measure serum titers of free T3 (FT3) and T4 (FT4), TSH, anti-TPO, and anti-Tg antibody titers. The thyroid sonography of each patient was classified into one of the five grades by real-time ultrasound (US) based on echogenicity, thyroid size, and thyroid pattern. We evaluated whether there was a correlation between thyroid characteristics observed via ultrasound and serum levels of thyroid hormones, anti-TPO antibodies, and anti-Tg antibodies.

RESULTS

Nodular structures were detected in 54 (36.2%) patients (38 micro-nodular and 16 macro-nodular). Echogenicity was recorded as isoechoic in 15(10.07%) and hypoechoic in 119 (79.87%) subjects. Euthyroid subjects had significantly thicker isthmus than overt and subclinical hypothyroid patients (P=0.018). Mean serum TSH, anti-Tg, and anti-TPO antibody titers showed a significant increase in patients with macro-nodules compared to those with micro-nodules and individuals without nodules (P0.05). The thickness of the isthmus had a significant negative correlation with FT4 (P=0.046; r=0.11) and FT3 (P=0.017; r=0.15), respectively. Thyroid autoantibodies had positive significant correlations with different parameters of thyroid volume (P0.05).

CONCLUSIONS

Thyroid US findings, in addition to serum anti-Tg and anti-TPO antibody titers, might be correlated with the severity and extent of Hashimoto's thyroiditis, but further evaluations are needed.

Для цитирования: Eftekharian Fatemeh, Ranjbar Omrani Gholamhossein, Dabbaghmanesh Mohammad Hossein, Sahraei Reza, Behnam Mohammad Ali, Bakhshayeshkaram Marzieh, Dabbaghmanesh Mohammad Mahdi. Comparison of Thyroid Gland Sonography Index with Serum Antithyroid Peroxidase, Antithyroglobulin, and Thyroid Function Tests in Patients with Hashimoto Thyroiditis.. Galen medical journal. 2024. DOI: 10.31661/gmj.v13i.3309.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.