MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jccase.2016.10.009

Медицинская библиотека · Journal of cardiology cases · 2016

Implantation of a MitraClip between two previously implanted MitraClips to treat recurrent severe mitral regurgitation.

Lesevic Hasema, Sonne Carolin, Kasel Albert Markus, Breuer Dietmar, Kastrati Adnan, Schunkert Heribert, Ott Ilka

Клинический случайСтатьяПеревод в очереди

Аннотация

We first describe the implantation of a MitraClip (Abbott Vascular, Abbott Park, IL, USA) between 2 previously implanted MitraClips to treat recurrent mitral regurgitation (MR). An 82-year-old male patient presented with dyspnea New York Heart Association NYHA class III due to recurrent severe MR 18 months after primarily successful implantation of 2 MitraClips. The initial procedure was performed to treat severe MR due to prolapse and flail of the anterior leaflet and resulted in mild MR after implantation of 2 MitraClips. Concomitant diseases were persistent atrial fibrillation, moderate tricuspid valve regurgitation, and chronic kidney disease stage 3. Thus, the patient was not considered a suitable candidate for surgical treatment. Using fluoroscopic guidance, 2D- and 3D-transesophageal echocardiographies, we succeeded in placing a third clip between the previously implanted clips and reduced the severe MR to mild MR without increase in the mean gradient. No periprocedural complications were observed. Six months after the procedure the patient presented with mild MR and NYHA class I. <Learning objective: Implantation of MitraClips offers the possibility of percutaneous mitral valve repair. It is feasible, safe, and effective to implant a 3rd MitraClip between 2 previously implanted MitraClips to treat recurrent mitral regurgitation between the clips.>.

Для цитирования: Lesevic Hasema, Sonne Carolin, Kasel Albert Markus, Breuer Dietmar, Kastrati Adnan, Schunkert Heribert, Ott Ilka. Implantation of a MitraClip between two previously implanted MitraClips to treat recurrent severe mitral regurgitation.. Journal of cardiology cases. 2016. DOI: 10.1016/j.jccase.2016.10.009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.