m+Medelevator.RU
← Поиск публикаций
Journal of vascular surgery · 2019

The presence of long and heavily calcified lesions predisposes for fracture in patients undergoing stenting of the first part of the subclavian artery.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hüttl András Béla, Hüttl Artúr, Vértes Miklós, Nguyen Dat Tin, Bérczi Ákos, Hüttl Kálmán, Dósa Edit

Аннотация

OBJECTIVE: To determine the prevalence and risk factors of subclavian artery stent fractures and to investigate their impact on in-stent restenosis development.

METHODS: One hundred eight patients (65 females; median age, 58.3 years [interquartile range, 53.4-65.5 years]) with steno-occlusive disease of the first part of the subclavian artery who underwent stenting (N = 108 stents; balloon-expandable, 83.3%; self-expandable, 16.7%) between 2005 and 2015 and returned for a fluoroscopic examination of the implanted stents in 2017 were included in our study. Fractures were type I (single strut fracture), type II (multiple strut fractures without deformation), type III (multiple strut fractures with deformation), type IV (multiple strut fractures with acquired transection but without gap), or type V (multiple strut fractures with acquired transection with gap in the stent body). Stent patency was monitored by duplex ultrasound imaging. The Mann-Whitney U and Fisher's exact tests; Kaplan-Meier, receiver operating characteristic, and logistic regression analyses; as well as a log-rank test were used as statistical methods.

RESULTS: The median follow-up was 73.8 months (interquartile range, 35.6-104.2 months). Thirty-eight fractures (35.2%) were detected; fractures were type I in 13, type II in 12, type III in 6, type IV in 4, and type V in 3 cases. Multivariable logistic regression analysis revealed the presence of long (≥20 mm) lesions (odds ratio, 3.3; 95% confidence interval, 1.3-8.4; P = .012) and heavy calcification (odds ratio, 4.7; 95% confidence interval, 1.7-12.7; P = .002) to be significant independent predictors of stent fracture. The primary patency rates were significantly worse (P = .035) in patients with stent fracture compared with those without stent fracture.

CONCLUSIONS: Stent fractures frequently occur. Patients with long and/or heavily calcified lesions require closer follow-up.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты