MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-020-01793-9

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2021

Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis.

Bugani Giulia, Pagnesi Matteo, Tchetchè Didier, Kim Won- Keun, Khokhar Arif, Sinning Jean- Malte, Landes Uri, Kornowski Ran, Codner Pablo, De Backer Ole, Nickenig Georg, Ielasi Alfonso, De Biase Chiara, Søndergaard Lars, De Marco Federico, Ancona Marco, Montorfano Matteo, Regazzoli Damiano, Stefanini Giulio, Toggweiler Stefan, Tamburino Corrado, Immè Sebastiano, Tarantini Giuseppe, Sievert Horst, Schäfer Ulrich, Kempfert Jörg, Wöehrle Jochen, Tespili Maurizio, Laricchia Alessandra, Latib Azeem, Giannini Francesco, Colombo Antonio, Mangieri Antonio

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To define the incidence of high residual gradient (HRG) after transcatheter aortic valve replacement (TAVR) in BAVs and their impact on short term outcome and 1-year mortality.

BACKGROUND

Transcatheter heart valves (THVs) offer good performance in tricuspid aortic valves with low rate of HRG. However, data regarding their performance in bicuspid aortic valves (BAV) are still lacking.

METHODS

The BEAT (Balloon vs Self-Expandable valve for the treatment of bicuspid Aortic valve sTenosis) registry included 353 consecutive patients who underwent TAVR (Evolut R/PRO or Sapien 3 valves) in BAV between June 2013 and October 2018. The primary endpoint was device unsuccess with post-procedural HRG (mean gradient ≥ 20 mmHg). The secondary endpoint was to identify the predictors of HRG following the procedure.

RESULTS

Twenty patients (5.6%) showed HRG after TAVR. Patients with HRG presented higher body mass index (BMI) (30.7 ± 9.3 vs. 25.9 ± 4.8; p < 0.0001) and higher baseline aortic mean gradients (57.6 ± 13.4 mmHg vs. 47.7 ± 16.6, p = 0.013) and more often presented with BAV of Sievers type 0 than patients without HRG. At multivariate analysis, BMI [odds ratio (OR) 1.12; 95% confidence interval (CI) 1.05-1.20, p = 0.001] and BAV type 0 (OR 11.31, 95% CI 3.45-37.06, p < 0.0001) were confirmed as independent predictors of high gradient.

CONCLUSION

HRG following TAVR in BAVs is not negligible and is higher among patients with high BMI and with BAV 0 anatomy.

Для цитирования: Bugani Giulia, Pagnesi Matteo, Tchetchè Didier, Kim Won- Keun, Khokhar Arif, Sinning Jean- Malte, Landes Uri, Kornowski Ran, Codner Pablo, De Backer Ole, Nickenig Georg, Ielasi Alfonso, De Biase Chiara, Søndergaard Lars, De Marco Federico, Ancona Marco, Montorfano Matteo, Regazzoli Damiano, Stefanini Giulio, Toggweiler Stefan, Tamburino Corrado, Immè Sebastiano, Tarantini Giuseppe, Sievert Horst, Schäfer Ulrich, Kempfert Jörg, Wöehrle Jochen, Tespili Maurizio, Laricchia Alessandra, Latib Azeem, Giannini Francesco, Colombo Antonio, Mangieri Antonio. Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis.. Clinical research in cardiology : official journal of the German Cardiac Society. 2021. DOI: 10.1007/s00392-020-01793-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.