MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12688/wellcomeopenres.20613.2

Медицинская библиотека · Wellcome open research · 2024

Determination of ivermectin in plasma and whole blood using LC-MS/MS.

Kaewkhao Natpapat, Hanpithakpong Warunee, Tarning Joel, Blessborn Daniel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ivermectin is a widely used drug for the treatment of helminthiasis and filariasis worldwide, and it has also shown promise for malaria elimination through its potent mosquito-lethal activity. The objective of this study was to develop and validate a high-throughput and sensitive method to quantify ivermectin in plasma and whole blood samples, using automated sample extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

METHODS

Phospholipids were removed in patient whole blood (100 µl) and plasma (100 µl) samples using a 96-well plate Hybrid-solid phase extraction technique. Ivermectin and its isotope-labelled internal standard (ivermectin-D2) were separated on an Agilent Poroshell 120 EC-C18 50mm × 3.0mm I.D. 2.7µm, using a mobile phase of acetonitrile: ammonium formate 2 mM containing 0.5% formic acid (90: 10, v/v). Detection was performed using a triple quadrupole mass spectrometer in the positive ionization mode.

RESULTS

The method was validated in the concentration range 0.970 - 384 ng/ml in both plasma and whole blood matrices. Intra- and inter-batch precisions during the validation were below 15%. There was no carryover or matrix effects detected. Ivermectin is a stable compound and results showed no degradation in the different stability tests.

CONCLUSIONS

The validated method proved to have high sensitivity and precision, good selectivity and to be suitable for clinical application or laboratory quantification of ivermectin in plasma or whole blood samples.

Для цитирования: Kaewkhao Natpapat, Hanpithakpong Warunee, Tarning Joel, Blessborn Daniel. Determination of ivermectin in plasma and whole blood using LC-MS/MS.. Wellcome open research. 2024. DOI: 10.12688/wellcomeopenres.20613.2.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.