MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2020.10.002

Медицинская библиотека · Journal of cardiovascular computed tomography · 2020

Short membranous septum length in bicuspid aortic valve stenosis increases the risk of conduction disturbances.

Hamdan Ashraf, Nassar Mithal, Schwammenthal Ehud, Perlman Gidon, Arow Ziad, Lessick Jonathan, Kerner Arthur, Barsheshet Alon, Assa Hana Vaknin, Assali Abid, Aviv Yaron, Goitein Orly, Brodov Yafim, Codner Pablo, Orvin Katia, Biton David, Klein Eyal, Danenberg Haim, Finkelstein Ariel, Kornowski Ran

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Distinct anatomical features predispose bicuspid AS patients to conduction disturbances after TAVR. This study sought to evaluate whether the incidence of permanent pacemaker implantation (PPMI) and left bundle branch block (LBBB) in patients with bicuspid aortic stenosis (AS) following transcatheter aortic valve replacement (TAVR) is related to an anatomical association between bicuspid AS and short membranous septal (MS) length.

METHODS

Sixty-seven consecutive patients with bicuspid AS from a Bicuspid AS TAVR multicenter registry and 67 propensity-matched patients with tricuspid AS underwent computed tomography before TAVR.

RESULTS

MS length was significantly shorter in bicuspid AS compared with tricuspid AS (6.2 ± 2.5 mm vs. 8.4 ± 2.7 mm, respectively; p < 0.001). In patients with bicuspid AS, MS length and aortic valve calcification were the most powerful pre-procedural independent predictors of PPMI or LBBB (odds ratio [OR]: 1.38, 95% confidence interval [CI]: 1.15 to 1.55, p = 0.003 and OR: 1.92, 95% CI: 1.1 to 3.34, p = 0.022, respectively). When taking into account pre- and post-procedural parameters, aortic valve calcification and the difference between MS length and implantation depth were the most powerful independent predictors of PPMI or LBBB in patients with bicuspid AS (OR: 1.82, 95%: 1.1 to 3.1, p = 0.027; OR: 1.25, 95% CI: 1.10 to 1.38, p = 0.003).

CONCLUSION

MS length, which was significantly shorter in bicuspid AS compared with tricuspid AS, aortic valve calcification, and device implantation deeper than MS length predict PPMI or LBBB in bicuspid AS after TAVR.

Для цитирования: Hamdan Ashraf, Nassar Mithal, Schwammenthal Ehud, Perlman Gidon, Arow Ziad, Lessick Jonathan, Kerner Arthur, Barsheshet Alon, Assa Hana Vaknin, Assali Abid, Aviv Yaron, Goitein Orly, Brodov Yafim, Codner Pablo, Orvin Katia, Biton David, Klein Eyal, Danenberg Haim, Finkelstein Ariel, Kornowski Ran. Short membranous septum length in bicuspid aortic valve stenosis increases the risk of conduction disturbances.. Journal of cardiovascular computed tomography. 2020. DOI: 10.1016/j.jcct.2020.10.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.