DOI 10.1007/s12194-026-01080-8

Медицинская библиотека · Radiological physics and technology · 2026

Clinical edge-case stress testing of two Asia-developed AI auto-contouring systems using prostate radiotherapy planning CT images.

Nagake Yuya, Yasui Keisuke, Sugiyama Ayami, Saito Yasunori, Shimizu Hidetoshi, Uezono Haruka, Hayashi Naoki

СтатьяПеревод в очереди

Аннотация

To compare the geometric accuracy of two Asia‑developed AI auto‑contouring systems (RatoGuide and OncoStudio) for prostate radiotherapy planning CT, including performance in clinical edge cases. Planning CT data from 45 patients were stratified into four groups (Normal, Spacer, Seed/Spacer, GM/Spacer). Manual contours of prostate, rectum, bladder, seminal vesicles, and femoral heads served as reference. Segmentation accuracy was assessed using DSC and 95% Hausdorff distance; Wilcoxon signed‑rank and Mann-Whitney U tests were applied, with edge‑case analyses treated as exploratory. Median DSC exceeded 0.7 for all structures. RatoGuide performed better for the rectum, whereas OncoStudio performed better for the bladder, seminal vesicles, and femoral heads. Outliers were concentrated in combined implant/spacer groups. Both tools showed generally favorable geometric agreement, with structure‑dependent advantages and edge‑case outliers that warrant workflow‑aware quality assurance and future dosimetric validation.

Для цитирования: Nagake Yuya, Yasui Keisuke, Sugiyama Ayami, Saito Yasunori, Shimizu Hidetoshi, Uezono Haruka, Hayashi Naoki. Clinical edge-case stress testing of two Asia-developed AI auto-contouring systems using prostate radiotherapy planning CT images.. Radiological physics and technology. 2026. DOI: 10.1007/s12194-026-01080-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.