MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2021.02.016

Медицинская библиотека · Academic radiology · 2021

Evaluating the Short-Term Clinical Efficacy of Magnetic Resonance Elastography in Patients with Budd-Chiari Syndrome.

Xu Peng, Lyu Lulu, Lu Xin, Hu Chunfeng, Xu Kai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

To investigate the clinical relevance of liver stiffness (LS) in evaluating liver function properties in patients with Budd-Chiari syndrome (BCS) with different severities and LS variation before and after endovascular intervention.

MATERIALS AND

METHODS

Between December 2016 and March 2019, patients with a diagnosis of BCS were considered for enrollment consecutively in our study. Liver function of these patients was classified according to Child-Pugh grading standard before treatment. Liver function parameters were recorded, including albumin, alanine aminotransferase, aspartate aminotransferase, prothrombin time, and total bilirubin. LS was measured with MR elastography (MRE) before and after treatment. Pearson correlation analysis was performed to measure the correlation between LS and liver function-related parameters. Univariate analysis of variance test was used to compare LS and clinical quantitative variables of patients in three different Child-Pugh categories. Paired t test with a significant threshold of p = 0.05 was used to compare LS and pressure gradient of these patients before and after treatment. Correlation analysis between changes in LS and that in pressure gradient was performed by linear regression.

RESULTS

A total of 43 patients (23 males and 20 females) were finally enrolled in this study. The mean LS in the three groups was 5.67 ± 1.15 kPa (Child-Pugh A), 6.31 ± 1.13 kPa (Child-Pugh B), and 8.27 ± 2.22 kPa (Child-Pugh C), respectively. LS showed significant difference for patients with different Child-Pugh grades (F = 9.536, p < 0.001). Prothrombin time and total bilirubin were positively correlated with LS (p < 0.05). After treatment, mean LS in three groups was 4.83 ± 1.06 kPa, 5.12 ± 0.93, and 7.37 ± 1.96, respectively. LS decreased significantly in all three Child-Pugh grades (p < 0.001 from Child-Pugh A, p < 0.001 from Child-Pugh B, p = 0.009 from Child-Pugh C). The mean pressure gradient before intervention was 17.6 ± 4.9 mm Hg, and 8.7 ± 7.2 mm Hg after the treatment (p < 0.001). The changes in LS were correlated to that in pressure gradients (r = 0.439; r2 = 0.193; p = 0.015).

CONCLUSION

MR elastography for LS measurement has been demonstrated to act as an effective tool to evaluate liver function, and to monitor the BCS patients in follow-up treatments.

Для цитирования: Xu Peng, Lyu Lulu, Lu Xin, Hu Chunfeng, Xu Kai. Evaluating the Short-Term Clinical Efficacy of Magnetic Resonance Elastography in Patients with Budd-Chiari Syndrome.. Academic radiology. 2021. DOI: 10.1016/j.acra.2021.02.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.