MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12877-025-05981-y

Медицинская библиотека · BMC geriatrics · 2025

Comparison of high-power single-ring isolation and box isolation in elderly patients with persistent atrial fibrillation.

Song Yanbin, Liang Xiaofang, Xue Sheliang, Xu Bo, Xiao Jianqiang, Li Wenhua

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

This study evaluated the superiority of single-ring isolation (SRI) over box isolation using high power in elderly patients with persistent atrial fibrillation (PeAF).

METHODS

We retrospectively studied elderly patients with PeAF who underwent primary catheter ablation. The patients were divided into the SRI group and the posterior box isolation (BOXI) group. Basic characteristics, procedural variables, complications and atrial arrhythmia recurrence rates were collected.

RESULTS

Forty-five pairs of patients in the two groups were matched by 1:1 PSM. Compared with that in the BOXI group, the total procedure time in the SRI group was not significantly different (P = 0.340). However, there were significant reductions in the total ablation time, ring ablation lesions and number of lesions on the posterior wall in patients who underwent SRI compared to those who underwent BOXI (all P < 0.001). The cardiac troponin level in the SRI group was significantly lower (P = 0.023). There were significantly fewer mismatched three-dimensional mapping models and mismatched models per patient due to pain-induced movement in the SRI group (all P < 0.05). The questionnaires revealed that the pain score was significantly lower in the SRI group than in the BOXI group (P < 0.001). In addition, significantly fewer patients with SRI than with BOXI experienced gastrointestinal symptoms after the procedure (15.56% vs. 37.78%, P = 0.017). K‒M analysis revealed no significant difference in atrial arrhythmia-free survival at 12 months between the SRI and BOXI patients (P > 0.05).

CONCLUSIONS

High-power SRI is safe and feasible and may be superior to the BOXI for experience of elderly patients with PeAF.

Для цитирования: Song Yanbin, Liang Xiaofang, Xue Sheliang, Xu Bo, Xiao Jianqiang, Li Wenhua. Comparison of high-power single-ring isolation and box isolation in elderly patients with persistent atrial fibrillation.. BMC geriatrics. 2025. DOI: 10.1186/s12877-025-05981-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.