Efficacy of additional lateral pinhole and SPECT/CT imaging in dual-phase Tc-99m MIBI parathyroid scintigraphy for localising parathyroid pathologies in patients with primary hyperparathyroidism: a single-institution experience.

Kesim Selin, Turoglu Halil Turgut, Kotan Tuncay, Balaban Genc Zeynep Ceren, Niftaliyeva Khanim, Toper Hasan, Gogas Yavuz Dilek, Ozguven Salih, Kaya Handan, Dede Fuat, Ugurlu Mustafa Umit, Oksuzoglu Kevser, Cagliyan Feyza, Gulluoglu Bahadir Mahmut, Ones Tunc, Erdil Tanju Yusuf

СтатьяПеревод в очереди

Аннотация

PURPOSE: Parathyroid imaging with dual-phase technetium-99m methoxyisobutrylizonitrile (Tc-99m MIBI) scintigraphy serves as an important prerequisite for the identification of hyperfunctioning parathyroid gland(s) in patients with primary hyperparathyroidism (PHPT) for a successful targeted parathyroidectomy. This study aimed to evaluate the clinical value of additional lateral imaging and single-photon emission computed tomography/computed tomography (SPECT/CT) versus conventional planar imaging for locating parathyroid pathologies in patients with PHPT.

MATERIALS AND

METHODS

A retrospective review was performed on 105 patients who underwent dual-phase Tc-99m MIBI scintigraphy and were surgically treated by parathyroidectomy. Dual-phase Tc-99m-MIBI planar scintigraphy with additional lateral pinhole views and SPECT/CT imaging was performed on a routine basis, as per departmental protocol. Comparison study between imaging modalities was done by patient-based analysis and scintigraphy results were compared with the clinical findings, biochemical markers, and histopathological findings.

RESULTS

Sensitivity and specificity for anterior planar dual-phase Tc-99m MIBI scintigraphy were 78.8 and 80%, respectively. In comparison, lateral pinhole scan and SPECT/CT alone were found to have sensitivities of 85.9 and 90.9%, respectively, with the same specificity. Sensitivity decreased in patients with normocalcaemia and multiglandular disease. The mean adenoma weight and size for true-positive studies were significantly higher than those for false-negative or false-positive studies.

CONCLUSION

SPECT/CT provided the highest diagnostic accuracy for preoperative identification of parathyroid lesions in PHPT patients. Lateral pinhole imaging offers comparable sensitivity and aids in adenoma localisation when SPECT/CT is unavailable.

Для цитирования: Kesim Selin, Turoglu Halil Turgut, Kotan Tuncay, Balaban Genc Zeynep Ceren, Niftaliyeva Khanim, Toper Hasan, Gogas Yavuz Dilek, Ozguven Salih, Kaya Handan, Dede Fuat, Ugurlu Mustafa Umit, Oksuzoglu Kevser, Cagliyan Feyza, Gulluoglu Bahadir Mahmut, Ones Tunc, Erdil Tanju Yusuf. Efficacy of additional lateral pinhole and SPECT/CT imaging in dual-phase Tc-99m MIBI parathyroid scintigraphy for localising parathyroid pathologies in patients with primary hyperparathyroidism: a single-institution experience.. Nuclear medicine communications. 2024. DOI: 10.1097/mnm.0000000000001924.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.