Journal of cardiovascular medicine (Hagerstown, Md.) · 2017
Cardiac resynchronization therapy outcomes in patients with chronic heart failure: cardiac resynchronization therapy with pacemaker versus cardiac resynchronization therapy with defibrillator.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Drozd Michael, Gierula John, Lowry Judith E, Paton Maria F, Joy Eleanor, Jamil Haqeel A, Cubbon Richard M, Kearney Mark T, Cairns David A, Witte Klaus K
Аннотация
AIMS: Cardiac resynchronization therapy (CRT) for chronic heart failure with left ventricular systolic dysfunction (LVSD) consistently improves survival against optimal medical therapy alone. Limited data exist comparing the outcomes between CRT with pacemaker (CRT-P) and with defibrillator (CRT-D). We aimed to investigate the long-term prognosis of patients who received CRT-P or CRT-D.
METHODS AND RESULTS: Data were prospectively collected from consecutive patients with standard indications for CRT, who were implanted at a single large tertiary centre between 2008 and 2012. All-cause mortality was compared between those patients who received either CRT-P or CRT-D. A subgroup analysis was performed in patients with ischaemic cardiomyopathy. During the period in question, 795 patients received CRT devices: 544 (68.4%) CRT-P and 251 (31.6%) CRT-D. The mean follow-up was 1072 ± (SD 556) days. Overall, there was no survival benefit in those patients implanted with a CRT-D compared with CRT-P (hazard ratio 1.09, 95% confidence interval 0.84-1.41, P = 0.51). In patients with ischaemic chronic heart failure [n = 530 (66.7%)], there was a trend for improved survival with CRT-D; however, this was not significant after adjustment. In a subgroup analysis, there were no differences in mode-specific mortality in those patients implanted with CRT-D compared with CRT-P.
CONCLUSION: In this large consecutive patient cohort, we did not find a survival benefit of CRT-D compared with CRT-P. Patients indicated for CRT devices may not reliably benefit from the addition of a defibrillator.
METHODS AND RESULTS: Data were prospectively collected from consecutive patients with standard indications for CRT, who were implanted at a single large tertiary centre between 2008 and 2012. All-cause mortality was compared between those patients who received either CRT-P or CRT-D. A subgroup analysis was performed in patients with ischaemic cardiomyopathy. During the period in question, 795 patients received CRT devices: 544 (68.4%) CRT-P and 251 (31.6%) CRT-D. The mean follow-up was 1072 ± (SD 556) days. Overall, there was no survival benefit in those patients implanted with a CRT-D compared with CRT-P (hazard ratio 1.09, 95% confidence interval 0.84-1.41, P = 0.51). In patients with ischaemic chronic heart failure [n = 530 (66.7%)], there was a trend for improved survival with CRT-D; however, this was not significant after adjustment. In a subgroup analysis, there were no differences in mode-specific mortality in those patients implanted with CRT-D compared with CRT-P.
CONCLUSION: In this large consecutive patient cohort, we did not find a survival benefit of CRT-D compared with CRT-P. Patients indicated for CRT devices may not reliably benefit from the addition of a defibrillator.
Предметные рубрики MeSH
AgedAged, 80 and overCardiac Resynchronization TherapyCardiac Resynchronization Therapy DevicesChronic DiseaseDefibrillators, ImplantableFemaleHeart FailureHumansMaleMiddle AgedProspective StudiesRisk FactorsSeverity of Illness IndexSurvival AnalysisTime FactorsTreatment OutcomeUnited KingdomVentricular Dysfunction, Left