Improving Falope-Ring application in laparoscopy training.
Аннотация
Laparoscopic Falope-Ring sterilization was performed by residents on 71 women. Immediately following application of the ring, methylene blue was injected through the cervix to assess tubal patency. Unilateral spillage of the dye was demonstrated in four patients (5.6%). In these instances a new ring was applied, or the tube was tied surgically. The high rate of tubal patency was attributed to the surgeons' inexperience. The findings suggest that the use of a patency test as an adjunct to sterilization with the Falope-Ring in training programs is likely to decrease the rate of surgical failures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.