MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.14621

Медицинская библиотека · Contact dermatitis · 2024

Nine years of patch testing with isocyanates in a clinic of occupational dermatology.

Aalto-Korte Kristiina, Pesonen Maria, Suomela Sari, Suuronen Katri

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Isocyanates are used as starting materials of polyurethane (PU) products. They are relatively important occupational skin sensitizers.

OBJECTIVES

To analyse results of a large isocyanate patch test series of 19 isocyanate test substances and 4,4'-diaminodiphenylmethane (MDA), a marker of 4,4'-diphenylmethane diisocyanate (MDI) hypersensitivity.

METHODS

Test files were screened for positive reactions in the isocyanate series. Patients with positive reactions were analysed for occupation, exposure and diagnosis.

RESULTS

In 2010-2019, 53 patients had positive reactions in the series (16% of 338 patients tested). MDA, the well-established screening substance for MDI allergy, was positive in 30 patients, an in-house monomeric MDI test substance in 23 patients and 3 different polymeric MDI test substances in 19-21 patients. We diagnosed 16 cases of occupational allergic contact dermatitis (OACD) from MDI including 3 pipe reliners. Hexamethylene-1,6-diisocyanate (HDI) oligomers in paint hardeners caused 5 cases of OACD, more cases than 2,4-toluene diisocyanate (TDI; n = 3) and isophorone diisocyanate (IPDI; n = 1) put together.

CONCLUSIONS

In contrast to previous studies, polymeric MDI test substances were not superior to a monomeric MDI. Pipe reliners may get sensitised not only by epoxy products and acrylates but also by MDI in hardeners of PU pipe coatings. HDI oligomers were the second most important causes of OACD after MDI.

Для цитирования: Aalto-Korte Kristiina, Pesonen Maria, Suomela Sari, Suuronen Katri. Nine years of patch testing with isocyanates in a clinic of occupational dermatology.. Contact dermatitis. 2024. DOI: 10.1111/cod.14621.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.