Prognostication of Liver Disease Patients via the WFUMB 'Rule-of-4' Algorithm Using SSI-2D-SWE-Based Liver Stiffness Measurement.
Аннотация
BACKGROUND
The World Federation for Ultrasound in Medicine and Biology (WFUMB) guidance update 2024 proposed a 'rule-of-4' using ARFI liver stiffness measurement (LSM) to stratify the risk of decompensation events. This rule identifies advanced chronic liver disease (ACLD) at a threshold of ≥ 13 kPa and indicates a high probability of clinically significant portal hypertension (CSPH) above 21 kPa.
METHODS
We prospectively enrolled 187 patients undergoing same-day SSI-2D-LSM (Aixplorer SuperSonic Imagine) and hepatic venous pressure gradient (HVPG) measurement. Patients were stratified into three LSM groups < 13 kPa, 13-21 kPa and > 21 kPa and followed for decompensation events for 1 year (Y1).
RESULTS
The cohort comprised 31 (16.6%) patients with LSM < 13 kPa (non-ACLD); 33 (17.6%) LSM 13-21 kPa (ACLD) and 123 (65.8%) LSM > 21 kPa (high CSPH probability). The corresponding median HVPG values were 5 [IQR: 3-7] vs. 10 [7-14] vs. 17 [13-21] mmHg, respectively, and the corresponding CSPH prevalence was 6.5%, 54.5% and 91.9%. In ROC analysis to predict CSPH, SSI-2D-LSM demonstrated high accuracy (AUC: 0.83). Validating the new WFUMB extension of the 'rule-of-4', the recommended > 21 kPa threshold identified CSPH with a specificity of 80.0% and a PPV of 83.1%. In competing risk analysis, the Y1-decompensation rate was 0%, 10% and 24.7% of patients in the < 13 kPa, 13-21 kPa and > 21 kPa groups, respectively. For prediction of Y1-decompensation risk in the compensated ACLD (cACLD) subgroup, HVPG demonstrated the highest predictive accuracy (AUC: 0.92), while SSI-2D-LSM (AUC: 0.75) performed similarly to vibration-controlled transient elastography (VCTE: AUC: 0.77; AUC-comparison: p = 0.837).
CONCLUSIONS
The WFUMB 'rule-of-4' for ARFI-LSM allows for accurate and point-of-care non-invasive risk stratification of patients with liver disease. Specifically, the short-term risk of decompensation starts at SSI-2D-LSM ≥ 13 kPa and becomes considerable at SSI-2D-LSM > 21 kPa (indicating high CSPH probability). These findings support the broader implementation of ARFI-LSM for risk assessment in clinical routine.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.