DOI 10.1016/j.ejso.2024.108648

Медицинская библиотека · European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology · 2024

Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy.

Kuo Ting-Chun, Chen Kuen-Yuan, Lai Chieh-Wen, Lin Ming-Tsan, Chang Chin-Hao, Wu Ming-Hsun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Preserving parathyroid function during thyroidectomy is crucial, but remains challenging. Real-time near-infrared autofluorescence (NIRAF) aids surgeons in intraoperative parathyroid gland (PTG) identification. However, its role in detecting PTGs unintentionally removed during surgery is unclear.

STUDY

DESIGN

This prospective study included adult patients undergoing endoscopic thyroidectomy. Surgeons identified and documented PTGs visually. Excised specimens underwent visual inspection and NIRAF imaging (PDE-Neo II). All fluorescent tissues were dissected and pathologically evaluated (reference standard). One scanned image per lobe was chosen to quantify autofluorescence (AF) intensity.

RESULTS

Overall, 95 patients underwent endoscopic thyroidectomies, with NIRAF imaging applied to 152 excised lobes. Of these, 19 lobes displayed a total of 23 spots with increased intensity. 175 specimens were sent for pathological evaluation, and 7 were confirmed to be parathyroid tissue. NIRAF demonstrated 100.0 % sensitivity and 90.5 % specificity for predicting parathyroid tissue, with 30.4 % positive predictive value, 100.0 % negative predictive value of and 90.9 % accuracy. Quantitatively normalized, the AF signal intensity was significantly higher in NIRAF-positive tissues than negative (4.3 vs 1.2 times, p < 0.0001). Additionally, the AF signal intensity in regions pathologically confirmed of parathyroid tissue was higher than non-parathyroid tissue (9.1 vs 2.1 times, p < 0.0001).

CONCLUSION

This study suggests that NIRAF has high sensitivity and specificity for detecting inadvertently resected PTGs after endoscopic thyroidectomy, contributing to preservation efforts. However, NIRAF-positive tissues still require additional confirmation through multiple methods, emphasizing other examinations to verify that they are indeed parathyroid tissues. Further research is warranted to refine NIRAF imaging parameters.

Для цитирования: Kuo Ting-Chun, Chen Kuen-Yuan, Lai Chieh-Wen, Lin Ming-Tsan, Chang Chin-Hao, Wu Ming-Hsun. Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy.. European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology. 2024. DOI: 10.1016/j.ejso.2024.108648.