PURPOSE: To test the hypothesis that procedural technique factors, particularly vessel preparation, would predict outcomes more strongly than anatomic complexity in patients with femoropopliteal in-stent restenosis (FP-ISR) treated with drug-coated balloons (DCBs).

MATERIALS AND

METHODS

From the PROMISING registry, 281 patients with FP-ISR underwent DCB treatment at 9 centers in China (2021-2023). The cohort had complex disease: 68.0% Tosaka Grade III total in-stent occlusions; mean total treated segment length, 26.0 cm (SD ± 11.4); 85.1% Trans-Atlantic Inter-Society Consensus C/D classification of the overall femoropopliteal segment; and 47.3% critical limb-threatening ischemia (CLTI). Primary endpoints were clinically driven target lesion revascularization (CD-TLR) and major adverse limb events (MALEs) at 12 months. Multivariable Cox regression analysis identified independent predictors.

RESULTS

At 12 months, cumulative incidence rates were 12.6% for CD-TLR and 14.1% for MALE. Major amputation occurred in 0.7%, and amputation-free survival was 92.9%. Quality of life improved substantially (Vascular Quality of Life questionnaire score, 2.6 [SD ± 0.9] to 5.3 [SD ± 1.2]; P < .001). Predilation was the strongest independent predictor of favorable outcomes (CD-TLR, hazard ratio [HR], 0.28 [95% CI, 0.14-0.59; P < .001]; MALE, HR, 0.28 [95% CI, 0.14-0.58; P < .001]), whereas CLTI predicted worse outcomes (CD-TLR, HR, 2.44 [P = .008]; MALE, HR, 2.25 [P = .015]). Lesion length of ≥250 mm and Tosaka Grade III occlusion patterns were not significant predictors.

CONCLUSIONS

In complex FP-ISR, adequate vessel preparation through predilation before DCB deployment was the strongest predictor of success, superseding anatomic complexity factors. These findings support routine predilation as a modifiable technical factor to optimize DCB outcomes in clinical practice.

Для цитирования: Du Ye, Chen Zhimin, Zhu Youpeng, Yang Wenbo, Ye Meng, Wu Ziheng, Feng Zibo. Drug-Coated Balloon Angioplasty for Femoropopliteal In-Stent Restenosis: Predictors and Outcomes from a Multicenter Study.. Journal of vascular and interventional radiology : JVIR. 2026. DOI: 10.1016/j.jvir.2026.108836.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.