Conditional organs-of-interest segmentation with plausible inter-fraction variation simulation for pancreatic magnetic resonance-guided radiotherapy in limited-data settings.

Shojaei Mehdi, Eiben Björn, McClelland Jamie R, Nill Simeon, Dunlop Alex, Chuter Robert W, Hunt Arabella, Ng-Cheng-Hin Brian, Oelfke Uwe

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Manual contouring of organs of interest (OoIs) is a major bottleneck in pancreatic magnetic resonance-guided online adaptive radiotherapy (oART). We developed C-SegDeform, a data-efficient conditional segmentation framework that used structure-guided deformation-based augmentations to simulate plausible inter-fraction anatomical variation and leveraged organ-specific conditioning as an alternative to registration-based contour propagation (Prop-ROIs) in limited-data settings.

MATERIALS AND

METHODS

Forty balanced 3DVane images from 12 patients were manually contoured and pre-processed, including duodenum, both kidneys, liver, large and small bowel, spinal canal, spleen, and stomach. The training dataset (26 images) was augmented by simulating plausible session images via structure-guided deformations. Data was arranged for conditional segmentation and leave-one-out cross-validation using the nnU-Net framework. Analysis included geometric (DSC, average surface distance (ASD), and 95th percentile of Hausdorff distance (HD95); against Prop-ROIs and TotalSegmentator MRI), dose (via 8 treatment plans, measuring D 0 . 1 c m 3 and D 50 % discrepancies relative to prescribed dose), and clinical (Likert scale and post-auto-contour editing times by two oncology consultants) assessments.

RESULTS

C-SegDeform (DSC: 0 . 88 ± 0 . 10 , ASD: 2 . 9 ± 2 . 4 mm , HD95: 10 . 5 ± 8 . 9 mm ) outperformed Prop-ROIs ( 0 . 70 ± 0 . 17 , 8 . 5 ± 9 . 9 mm , 16 . 7 ± 9 . 8 mm ) and TotalSegmentator ( 0 . 75 ± 0 . 16 , 5 . 1 ± 3 . 4 mm , 14 . 3 ± 10 . 6 mm ), and showed smaller relative dose deviations from ground-truth contours ( D 0 . 1 c m 3 : 2 . 2 % ± 2 . 5 % , D 50 % : 0 . 5 % ± 0 . 9 % ) than Prop-ROIs ( 6 . 8 % ± 5 . 7 % , 3 . 3 % ± 4 . 0 % ). Clinicians ranked 98% of C-SegDeform contours as requiring no or minor edits (vs. 70% for Prop-ROIs), with editing times under 6 min and full OoI generation completed in under 40 s.

CONCLUSIONS

C-SegDeform provided a robust alternative to contour propagation, generating accurate contours rapidly with minimal edits, thereby reducing on-couch time and streamlining the workflow.

Для цитирования: Shojaei Mehdi, Eiben Björn, McClelland Jamie R, Nill Simeon, Dunlop Alex, Chuter Robert W, Hunt Arabella, Ng-Cheng-Hin Brian, Oelfke Uwe. Conditional organs-of-interest segmentation with plausible inter-fraction variation simulation for pancreatic magnetic resonance-guided radiotherapy in limited-data settings.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.100973.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.