Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy.

Abdollahi Sara, Mowlavi Ali Asghar, Yazdi Mohammad Hadi Hadizadeh, Ceberg Sofie, Aznar Marianne Camille, Tabrizi Fatemeh Varshoee, Salek Roham, Guckenberger Matthias, Tanadini-Lang Stephanie

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Motion management techniques are important to spare the healthy tissue adequately. However, they are complex and need dedicated quality assurance. The aim of this study was to create a dynamic phantom designed for quality assurance and to replicate a patient's size, anatomy, and tissue density.

MATERIALS AND

METHODS

A computed tomography (CT) scan of a cancer patient was used to create molds for the lungs, heart, ribs, and vertebral column via additive manufacturing. A pump system and software were developed to simulate respiratory dynamics. The extent of respiratory motion was quantified using a 4DCT scan. End-to-end tests were conducted to evaluate two motion management techniques for lung stereotactic body radiotherapy (SBRT).

RESULTS

The chest wall moved between 4 mm and 13 mm anteriorly and 2 mm to 7 mm laterally during the breathing. The diaphragm exhibited superior-inferior movement ranging from 5 mm to 16 mm in the left lung and 10 mm to 36 mm in the right lung. The left lung tumor displaced ± 7 mm superior-inferiorly and anterior-posteriorly. The CT numbers were for lung: -716 ± 108 HU (phantom) and -713 ± 70 HU (patient); bone: 460 ± 20 HU (phantom) and 458 ± 206 HU (patient); soft tissue: 92 ± 9 HU (phantom) and 60 ± 25 HU (patient). The end-to-end testing showed an excellent agreement between the measured and the calculated dose for ion chamber and film dosimetry.

CONCLUSIONS

The phantom is recommended for quality assurance, evaluating the institution's specific planning and motion management strategies either through end-to-end testing or as an external audit phantom.

Для цитирования: Abdollahi Sara, Mowlavi Ali Asghar, Yazdi Mohammad Hadi Hadizadeh, Ceberg Sofie, Aznar Marianne Camille, Tabrizi Fatemeh Varshoee, Salek Roham, Guckenberger Matthias, Tanadini-Lang Stephanie. Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100587.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.