Ultrasound evaluation of diaphragm function in mechanically ventilated patients: comparison to phrenic stimulation and prognostic implications.

Dubé Bruno-Pierre, Dres Martin, Mayaux Julien, Demiri Suela, Similowski Thomas, Demoule Alexandre

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE: In intensive care unit (ICU) patients, diaphragm dysfunction is associated with adverse clinical outcomes. Ultrasound measurements of diaphragm thickness, excursion (EXdi) and thickening fraction (TFdi) are putative estimators of diaphragm function, but have never been compared with phrenic nerve stimulation. Our aim was to describe the relationship between these variables and diaphragm function evaluated using the change in endotracheal pressure after phrenic nerve stimulation (Ptr,stim), and to compare their prognostic value.

METHODS

Between November 2014 and June 2015, Ptr,stim and ultrasound variables were measured in mechanically ventilated patients <24 hours after intubation ('initiation of mechanical ventilation (MV)', under assist-control ventilation, ACV) and at the time of switch to pressure support ventilation ('switch to PSV'), and compared using Spearman's correlation and receiver operating characteristic curve analysis. Diaphragm dysfunction was defined as Ptr,stim <11 cm H2O.

RESULTS

112 patients were included. At initiation of MV, Ptr,stim was not correlated to diaphragm thickness (p=0.28), EXdi (p=0.66) or TFdi (p=0.80). At switch to PSV, TFdi and EXdi were respectively very strongly and moderately correlated to Ptr,stim, (r=0.87, p<0.001 and 0.45, p=0.001), but diaphragm thickness was not (p=0.45). A TFdi <29% could reliably identify diaphragm dysfunction (sensitivity and specificity of 85% and 88%), but diaphragm thickness and EXdi could not. This value was associated with increased duration of ICU stay and MV, and mortality.

CONCLUSIONS

Under ACV, diaphragm thickness, EXdi and TFdi were uncorrelated to Ptr,stim. Under PSV, TFdi was strongly correlated to diaphragm strength and both were predictors of remaining length of MV and ICU and hospital death.

Для цитирования: Dubé Bruno-Pierre, Dres Martin, Mayaux Julien, Demiri Suela, Similowski Thomas, Demoule Alexandre. Ultrasound evaluation of diaphragm function in mechanically ventilated patients: comparison to phrenic stimulation and prognostic implications.. Thorax. 2017. DOI: 10.1136/thoraxjnl-2016-209459.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.