Fukuda Haruka, Kitamura Mineaki, Ishii Takuma, Kusumoto Yoko, Itoh Itsuho, Torigoe Kenta, Yamashita Hiroshi, Takehara Kosuke, Watanabe Junichi, Imamura Ryoichi, Mukae Hiroshi, Nishino Tomoya

Клинический случайСтатьяПеревод в очереди

Аннотация

Drainage failure during peritoneal dialysis is most commonly due to mechanical complications, such as catheter migration and obstruction. However, intraperitoneal catheter rupture is extremely rare. We report the case of a 48-year-old man with autosomal dominant polycystic kidney disease (ADPKD) who developed intraperitoneal catheter rupture. Despite a thorough analysis of the removed catheter, the definitive cause of rupture could not be determined. Chronic mechanical stress, exacerbated by obesity (body mass index 40.74 kg/m2), was thought to induce catheter rupture. Additionally, the peritoneal wall anchor technique may be associated with mechanical stress. Patients with obesity and ADPKD are at a high risk of catheter rupture. Therefore, intraperitoneal catheter rupture should be considered a differential diagnosis when investigating the cause of poor drainage in patients undergoing peritoneal dialysis.

Для цитирования: Fukuda Haruka, Kitamura Mineaki, Ishii Takuma, Kusumoto Yoko, Itoh Itsuho, Torigoe Kenta, Yamashita Hiroshi, Takehara Kosuke, Watanabe Junichi, Imamura Ryoichi, Mukae Hiroshi, Nishino Tomoya. Peritoneal catheter rupture in an obese patient with the peritoneal wall anchor technique.. CEN case reports. 2026. DOI: 10.1007/s13730-025-01053-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.