MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejro.2026.100772

Медицинская библиотека · European journal of radiology open · 2026

TotalSegmentator-AI for aortic segmentation in CT: Reliable performance in normal anatomy but limited utility in pathological aortic disease.

El Rahal Dania, Pozzessere Chiara, Gulizia Marianna, Rotzinger David C, Fahrni Guillaume

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Accurate aortic segmentation on computed tomography angiography (CTA) is essential for diagnosing aortic disease, cardiovascular risk assessment, and surgical planning. Deep learning algorithms, such as TotalSegmentator-AI, offer fully automated multi-organ segmentation, yet their performance in pathological aortic conditions remains uncertain. This study performs a clinical stress-test of TotalSegmentator-AI, mapping its boundaries and structural failure modes across a spectrum of normal and pathological cases.

METHODS

In this monocentric, retrospective study, 60 CTA scans from 2014 to 2024 were categorized into six groups: young, elderly, aneurysm, dissection, venous phase, and non-contrast phase. TotalSegmentator-AI was applied without manual correction. Two radiologists independently rated six aortic segments per scan using a five-point qualitative scale. Quantitative segmentation errors were correlated with qualitative scores using Spearman's correlation, and inter-reader agreement was assessed with weighted Cohen's kappa.

RESULTS

All scans were successfully processed, yielding 360 aortic segments. Median segmentation quality was 4 [IQR 4-5], with 77% rated good or excellent. Performance was consistent across segments (p = 0.16) but varied by category (p < 0.001): best in young patients (5 [IQR 4-5]) and adequate in non-contrast and venous-phase scans (4 [IQR 4-5]), poorest in dissections (3 [IQR 3-4]) and aneurysms (4 [IQR 3-4]). A strong negative correlation was observed between qualitative scores and quantitative errors (ρ = -1, p = 0.017). Inter-reader agreement was substantial (κ = 0.72).

CONCLUSION

TotalSegmentator-AI achieves accurate aortic segmentation in normal anatomy but is inadequate for unsupervised clinical use in complex pathologies like aneurysms and dissections. Comprehensive human-in-the-loop quality control or dedicated pathology-inclusive models are mandatory before AI-based segmentation can be safely integrated into vascular clinical workflows.

Для цитирования: El Rahal Dania, Pozzessere Chiara, Gulizia Marianna, Rotzinger David C, Fahrni Guillaume. TotalSegmentator-AI for aortic segmentation in CT: Reliable performance in normal anatomy but limited utility in pathological aortic disease.. European journal of radiology open. 2026. DOI: 10.1016/j.ejro.2026.100772.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.