BACKGROUND

In this study, we describe the technique of eversion of the native aortic tissue to prevent suture line complications, and report on our results with this technique.

METHODS

A total of 42 patients who were operated on due to aortic aneurysm were retrospectively assessed. In all patients, an aortic segment of approximately 2 cm, which was left both distally and proximally, was everted to form a double-layer lumen and the grafts were anastomosed. Postoperative outcomes and long-term follow-up results were assessed.

RESULTS

Aortic root replacement was done in 14 cases and eight subjects underwent concurrent coronary artery bypass surgery. Postoperatively, the average volume of the drainage was 375 ± 75 ml, and there were no re-operations. Twenty-seven patients required blood transfusion.

CONCLUSIONS

Reinforcement of the anastomosis line via eversion of the native aortic tissue reduced peri-operative blood loss and pseudo-aneurysm and infection, with the advantage of using viable tissue.

Для цитирования: Kaya Erhan. Reinforcement of suture lines with aortic eversion in aortic replacement.. Cardiovascular journal of Africa. 2018. DOI: 10.5830/cvja-2017-008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.