MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/os.14268

Медицинская библиотека · Orthopaedic surgery · 2024

Applying 3D-Printed Porous Ti6Al4V Prostheses to Repair Osteomyelitis-Induced Partial Bone Defects of Lower Limbs: Finite Element Analysis and Clinical Outcomes.

Liu Bingchuan, Tan Qizhao, Wang Zhengguang, Hou Guojin, Wang Caimei, Tian Yun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The clinical management of partial bone defects in lower limbs, particularly those resulting from osteomyelitis, remains a significant challenge. This study aimed to systematically evaluate the effectiveness of 3D-printed porous Ti6Al4V prostheses in addressing osteomyelitis-induced partial bone defects.

METHODS

We established a comprehensive protocol for utilizing 3D-printed prostheses for bone defect repair, encompassing 3D simulation of prosthesis implantation and internal fixation, finite element analysis (FEA), and clinical implementation. Mimics software facilitated simulation of fixation patterns and screw lengths. FEA modeled bone defects in the distal metaphyseal femur and distal diaphyseal tibia to assess changes in stress conduction pre- and post-prosthesis implantation. The clinical study involved eight patients (average age: 56.3 years) with an average defect length of 14.9 cm. Postoperative outcomes were evaluated using X-rays and the Lower Extremity Functional Scale (LEFS).

RESULTS

FEA demonstrated that the implanted prostheses effectively shared stress and reduced the load on residual bone in both models, thus lowering the risk of fractures under external forces. The average follow-up period was 24.5 months, with patients initiating weight-bearing activities on average 7.8 days post-surgery. Serial postoperative X-rays demonstrated long-term stability of the prostheses, with progressive bone regeneration around and integration with the prostheses. While two patients experienced infection recurrence requiring prosthesis removal and debridement, the remaining six showed significant improvement in LEFS scores, increasing from 31.5 preoperatively to 61.0 at the last follow-up.

CONCLUSIONS

3D-printed porous Ti6Al4V prostheses effectively restore anatomical integrity and optimize stress conduction in lower limbs, resulting in substantial functional recovery. This innovative approach shows promise for wider clinical adoption and warrants further investigation in medical practice.

Для цитирования: Liu Bingchuan, Tan Qizhao, Wang Zhengguang, Hou Guojin, Wang Caimei, Tian Yun. Applying 3D-Printed Porous Ti6Al4V Prostheses to Repair Osteomyelitis-Induced Partial Bone Defects of Lower Limbs: Finite Element Analysis and Clinical Outcomes.. Orthopaedic surgery. 2024. DOI: 10.1111/os.14268.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.