MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2015-308939

Медицинская библиотека · Heart (British Cardiac Society) · 2016

Performance of 2014 NICE defibrillator implantation guidelines in heart failure risk stratification.

Cubbon Richard M, Witte Klaus K, Kearney Lorraine C, Gierula John, Byrom Rowenna, Paton Maria, Sengupta Anshuman, Patel Peysh A, Mn Walker Andrew, Cairns David A, Rajwani Adil, Hall Alistair S, Sapsford Robert J, Kearney Mark T

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Define the real-world performance of recently updated National Institute for Health and Care Excellence guidelines (TA314) on implantable cardioverter-defibrillator (ICD) use in people with chronic heart failure.

METHODS

Multicentre prospective cohort study of 1026 patients with stable chronic heart failure, associated with left ventricular ejection fraction (LVEF) ≤45% recruited in cardiology outpatient departments of four UK hospitals. We assessed the capacity of TA314 to identify patients at increased risk of sudden cardiac death (SCD) or appropriate ICD shock.

RESULTS

The overall risk of SCD or appropriate ICD shock was 2.1 events per 100 patient-years (95% CI 1.7 to 2.6). Patients meeting TA314 ICD criteria (31.1%) were 2.5-fold (95% CI 1.6 to 3.9) more likely to suffer SCD or appropriate ICD shock; they were also 1.5-fold (95% CI 1.1 to 2.2) more likely to die from non-cardiovascular causes and 1.6-fold (95% CI 1.1 to 2.3) more likely to die from progressive heart failure. Patients with diabetes not meeting TA314 criteria experienced comparable absolute risk of SCD or appropriate ICD shock to patients without diabetes who met TA314 criteria. Patients with ischaemic cardiomyopathy not meeting TA314 criteria experienced comparable absolute risk of SCD or appropriate ICD shock to patients with non-ischaemic cardiomyopathy who met TA314 criteria.

CONCLUSIONS

TA314 can identify patients with reduced LVEF who are at increased relative risk of sudden death. Clinicians should also consider clinical context and the absolute risk of SCD when advising patients about the potential risks and benefits of ICD therapy.

Для цитирования: Cubbon Richard M, Witte Klaus K, Kearney Lorraine C, Gierula John, Byrom Rowenna, Paton Maria, Sengupta Anshuman, Patel Peysh A, Mn Walker Andrew, Cairns David A, Rajwani Adil, Hall Alistair S, Sapsford Robert J, Kearney Mark T. Performance of 2014 NICE defibrillator implantation guidelines in heart failure risk stratification.. Heart (British Cardiac Society). 2016. DOI: 10.1136/heartjnl-2015-308939.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.