MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.70248

Медицинская библиотека · The Laryngoscope · 2025

A Randomized Controlled Trial of Intraoperative Nerve Monitoring in Resident-Performed Thyroidectomy.

Maneeprasopchoke Prachya, Chayasitthangkul Thikhampone, Chongkolwatana Cheerasook, Chumpathong Saowapark, Randolph Gregory W, Russell Marika D, Abdelhamid-Ahmed Amr H, Pithuksurachai Paveena

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Intraoperative nerve monitoring (IONM) is widely used in thyroidectomy to aid recurrent laryngeal nerve (RLN) identification and preservation. This study assessed whether IONM improves RLN identification time and overall operative time in less experienced otorhinolaryngology residents performing thyroidectomies.

METHODS

This randomized controlled trial was conducted at Siriraj Hospital, Bangkok, from January 2020 to February 2021. A total of 80 patients were randomly assigned to an IONM or non-IONM group. A total of 10 residents performed eight thyroidectomies each, using IONM in four procedures and non-IONM methods in the other four.

RESULTS

RLN identification was significantly quicker in the IONM group (6.7 vs. 19.7 min for primary identification, 11.0 vs. 19.7 min for visual identification). IONM increased setup and nerve dissection time but without significant differences in overall operative time or RLN injury rates.

CONCLUSIONS

IONM improves RLN identification efficiency in surgical training but does not significantly impact overall operative time or RLN injury rates.

TRIAL REGISTRATION: Clinical Trials Registry (TCTR20191224001).

Для цитирования: Maneeprasopchoke Prachya, Chayasitthangkul Thikhampone, Chongkolwatana Cheerasook, Chumpathong Saowapark, Randolph Gregory W, Russell Marika D, Abdelhamid-Ahmed Amr H, Pithuksurachai Paveena. A Randomized Controlled Trial of Intraoperative Nerve Monitoring in Resident-Performed Thyroidectomy.. The Laryngoscope. 2025. DOI: 10.1002/lary.70248.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.