Infrared Pedal Temperature and Non-Invasive Vascular Tests in Peripheral Artery Disease: Pilot Study.
Аннотация
INTRODUCTION
Ankle/toe-brachial indexes (ABI/TBI) are the gold standard for assessing distal arterial flow but require in-person testing. This pilot study evaluated infrared thermometry as a non-invasive screening tool by assessing its correlation with TBI in peripheral arterial disease (PAD) patients following revascularization.
METHODS
PAD patients undergoing revascularization were enrolled from January 2024 to November 2024. Foot temperature was measured using the Exergen DermaTemp DT-2000-BT FootScanner at six anatomical locations. Subjects were categorized into wound and non-wound groups. Pearson and Spearman correlations assessed TBI-temperature relationships; Mann-Whitney U test compared groups.
RESULTS
Among 37 patients, 37.8% had foot wounds. Significant negative correlations were observed between TBI and temperature at the 1st metatarsal (R = -0.39, P = 0.035) and midfoot (R = -0.44, P = 0.018). The wound group had lower ABIs (0.57 versus 0.81, P < 0.001), lower toe pressures (42.5 versus 54.0 mmHg, P < 0.0001), and higher temperatures across all foot regions (P < 0.0001). In the wound group, higher TBI correlated with temperatures within the expected physiological range at the hallux (R = -0.67, P = 0.017), 1st metatarsal (R = -0.67, P = 0.018), and 3rd metatarsal (R = -0.62, P = 0.033). No significant correlations were observed in the non-wound group.
CONCLUSIONS
Infrared thermometry demonstrated significant negative correlations between foot temperature and TBI. In patients with foot wounds, adequate perfusion was associated with efficient regulation of the inflammatory response, resulting in temperatures within the expected physiological range. In contrast, compromised perfusion was associated with impaired heat dissipation and persistent inflammation, leading to elevated local temperatures. These findings support infrared thermometry as a complementary, non-invasive monitoring tool for PAD patients and warrant validation in larger studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.